Queries, comments, suggestions? Please contact us.



Area Lighting / Colorimetry

IEV ref 845-23-066

Symbol
pe

en
excitation purity
quotient NC/ND of two collinear distances on the chromaticity diagram of the CIE 1931 or 1964 standard colorimetric systems, the first distance being that between the point C representing the colour stimulus considered and the point N representing the specified achromatic stimulus, the second distance being that between the point N and the point D on the spectrum locus at the dominant wavelength of the colour stimulus considered, leading to the following expressions:

p e = y y n y d y n MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX garuavP1wzZbItLDhis9wBH5garmWu51MyVXgaruWqVvNCPvMCG4uz 3bqee0evGueE0jxyaibaieYdi9WrpeeC0lXdh9vqqj=hEeea0xXdbb a9frFj0=OqFfea0dXdd9vqaq=JfrVkFHe9pgea0dXdar=Jb9hs0dXd bPYxe9vr0=vr0=vqpWqaaeaaciWacmGadaGadeaaeaGaauaaaOqaai aadchadaWgaaWcbaGaaeyzaaqabaGccqGH9aqpdaWcaaqaaiaadMha cqGHsislcaWG5bWaaSbaaSqaaiaab6gaaeqaaaGcbaGaamyEamaaBa aaleaacaqGKbaabeaakiabgkHiTiaadMhadaWgaaWcbaGaaeOBaaqa baaaaaaa@4376@

and

p e = x x n x d x n MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX garuavP1wzZbItLDhis9wBH5garmWu51MyVXgaruWqVvNCPvMCG4uz 3bqee0evGueE0jxyaibaieYdi9WrpeeC0lXdh9vqqj=hEeea0xXdbb a9frFj0=OqFfea0dXdd9vqaq=JfrVkFHe9pgea0dXdar=Jb9hs0dXd bPYxe9vr0=vr0=vqpWqaaeaaciWacmGadaGadeaaeaGaauaaaOqaai aadchadaWgaaWcbaGaaeyzaaqabaGccqGH9aqpdaWcaaqaaiaadIha cqGHsislcaWG4bWaaSbaaSqaaiaab6gaaeqaaaGcbaGaamiEamaaBa aaleaacaqGKbaabeaakiabgkHiTiaadIhadaWgaaWcbaGaaeOBaaqa baaaaaaa@4372@

where (x, y), (xn, yn), (xd, yd) are the x, y chromaticity coordinates of the points C, N and D respectively

Note 1 to entry: In the case of purple stimuli, the monochromatic stimulus is replaced by a stimulus whose chromaticity is represented by a point on the purple boundary.

Note 2 to entry: The formulae in x and y are equivalent, but greater precision is given by the formula which has the greater value in the numerator.

Note 3 to entry: The excitation purity, pe, is related to the colorimetric purity, pc, by the equation:

p e = p c y y d MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX garuavP1wzZbItLDhis9wBH5garmWu51MyVXgaruWqVvNCPvMCG4uz 3bqee0evGueE0jxyaibaieYdi9WrpeeC0lXdh9vqqj=hEeea0xXdbb a9frFj0=OqFfea0dXdd9vqaq=JfrVkFHe9pgea0dXdar=Jb9hs0dXd bPYxe9vr0=vr0=vqpWqaaeaaciWacmGadaGadeaaeaGaauaaaOqaai aadchadaWgaaWcbaGaaeyzaaqabaGccqGH9aqpdaWcaaqaaiaadcha daWgaaWcbaGaae4yaaqabaGccaWG5baabaGaamyEamaaBaaaleaaca qGKbaabeaaaaaaaa@3F63@

Note 4 to entry: The excitation purity has unit one.

Note 5 to entry: This entry was numbered 845-03-48 in IEC 60050-845:1987.


fr
pureté d'excitation, f
quotient NC/ND de deux distances colinéaires mesurées sur le diagramme de chromaticité des systèmes de référence colorimétriques CIE 1931 ou 1964, la première distance étant celle entre le point C représentant le stimulus de couleur pris en considération et le point N représentant le stimulus achromatique spécifié; la seconde distance est celle entre le point N et le point D sur le lieu spectral à la longueur d'onde dominante du stimulus de couleur pris en considération. La définition conduit aux expressions suivantes:

p e = y y n y d y n MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX garuavP1wzZbItLDhis9wBH5garmWu51MyVXgaruWqVvNCPvMCG4uz 3bqee0evGueE0jxyaibaieYdi9WrpeeC0lXdh9vqqj=hEeea0xXdbb a9frFj0=OqFfea0dXdd9vqaq=JfrVkFHe9pgea0dXdar=Jb9hs0dXd bPYxe9vr0=vr0=vqpWqaaeaaciWacmGadaGadeaaeaGaauaaaOqaai aadchadaWgaaWcbaGaaeyzaaqabaGccqGH9aqpdaWcaaqaaiaadMha cqGHsislcaWG5bWaaSbaaSqaaiaab6gaaeqaaaGcbaGaamyEamaaBa aaleaacaqGKbaabeaakiabgkHiTiaadMhadaWgaaWcbaGaaeOBaaqa baaaaaaa@4376@

et

p e = x x n x d x n MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX garuavP1wzZbItLDhis9wBH5garmWu51MyVXgaruWqVvNCPvMCG4uz 3bqee0evGueE0jxyaibaieYdi9WrpeeC0lXdh9vqqj=hEeea0xXdbb a9frFj0=OqFfea0dXdd9vqaq=JfrVkFHe9pgea0dXdar=Jb9hs0dXd bPYxe9vr0=vr0=vqpWqaaeaaciWacmGadaGadeaaeaGaauaaaOqaai aadchadaWgaaWcbaGaaeyzaaqabaGccqGH9aqpdaWcaaqaaiaadIha cqGHsislcaWG4bWaaSbaaSqaaiaab6gaaeqaaaGcbaGaamiEamaaBa aaleaacaqGKbaabeaakiabgkHiTiaadIhadaWgaaWcbaGaaeOBaaqa baaaaaaa@4372@

où (x, y), (xn, yn), (xd, yd) sont respectivement les coordonnées trichromatiques sur les axes x, y des points C, N et D

Note 1 à l'article: Dans le cas de stimuli pourpres, le stimulus monochromatique est remplacé par un stimulus dont la chromaticité est représentée par un point sur la limite des pourpres.

Note 2 à l'article: Les expressions en x et en y sont équivalentes, mais l'emploi de celle qui donne au numérateur la plus grande valeur conduit à une meilleure précision.

Note 3 à l'article: La pureté d'excitation, pe, est liée à la pureté colorimétrique, pc, par la relation:

p e = p c y y d MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX garuavP1wzZbItLDhis9wBH5garmWu51MyVXgaruWqVvNCPvMCG4uz 3bqee0evGueE0jxyaibaieYdi9WrpeeC0lXdh9vqqj=hEeea0xXdbb a9frFj0=OqFfea0dXdd9vqaq=JfrVkFHe9pgea0dXdar=Jb9hs0dXd bPYxe9vr0=vr0=vqpWqaaeaaciWacmGadaGadeaaeaGaauaaaOqaai aadchadaWgaaWcbaGaaeyzaaqabaGccqGH9aqpdaWcaaqaaiaadcha daWgaaWcbaGaae4yaaqabaGccaWG5baabaGaamyEamaaBaaaleaaca qGKbaabeaaaaaaaa@3F63@

Note 4 à l'article: L'unité de pureté d'excitation est un.

Note 5 à l'article: Cet article était numéroté 845-03-48 dans l'IEC 60050-845:1987.


ar
نقاوة التهيج, <لمحفزلونى>
نقاوة الإثارة

cs
souřadnicová čistota

de
spektraler Farbanteil, m

it
purezza di eccitazione

ko
자극 순도

ja
刺激純度

nl
nl verzadigingsgraad

nl
be kleurverzadigingsgraad, m

pl
czystość pobudzenia, f

pt
pureza de excitação

zh
兴奋纯度

Publication date: 2020-12
Copyright © IEC 2024. All Rights Reserved.