Print
Export
Attributes
Class
Class and superclasses
Class and subclasses
Composition
Properties
Class
Class and superclasses
Class and subclasses
All
Class
Class and superclasses
<
>
Print
Export
Properties\Class properties
Properties\Class and superclasses
Properties\Class and subclasses
English
French
German
Japanese
Chinese
CLASS
Code:
0112/2///62683#ACC012
Version:
003
Revision:
01
IRDI:
0112/2///62683#ACC012#003
Preferred name:
General technical data
Synonymous name:
Coded name:
Short name:
Definition:
general technical aspects of the device
Note:
Remark:
Definition source:
Drawing:
Class type:
ITEM_CLASS
Applicable documents:
Class value assignment:
Requisity of properties:
Superclass:
0112/2///62683#ACC010
Higher level classes:
0112/2///62683#ACC001 - LV switchgear and controlgear domain
Classifying DET:
Properties:
Properties:
0112/2///62683#ACE247 - degree of protection of front face
0112/2///62683#ACE248 - degree of protection of terminals
0112/2///62683#ACE204 - isolating function
0112/2///62683#ACE243 - provision for locking
0112/2///62683#ACE239 - motor-operator
.....
0112/2///62683#ACE247 - degree of protection of front face
0112/2///62683#ACE248 - degree of protection of terminals
0112/2///62683#ACE204 - isolating function
0112/2///62683#ACE243 - provision for locking
0112/2///62683#ACE239 - motor-operator
0112/2///62683#ACE219 - type of associated circuit-breaker
0112/2///62683#ACE424 - rated current
0112/2///62683#ACE206 - suitable for use in single phase
0112/2///62683#ACE218 - degree of protection of the device
0112/2///62683#ACE234 - main contact fully visible in open position
0112/2///62683#ACE236 - double opening of the circuit
0112/2///62683#ACE215 - type of over-current release
0112/2///62683#ACE213 - trip class
0112/2///62683#ACE207 - self-powered device
0112/2///62683#ACE208 - nature of the reset of the overload release
0112/2///62683#ACE216 - built-in current sensor
0112/2///62683#ACE205 - load shedding
0112/2///62683#ACE220 - ground/earth fault detection
0112/2///62683#ACE222 - jam detection
0112/2///62683#ACE221 - stall detection
0112/2///62683#ACE223 - over and/or under current detection
0112/2///62683#ACE224 - over and/or under voltage detection
0112/2///62683#ACE225 - current imbalance detection
0112/2///62683#ACE227 - phase reversal detection
0112/2///62683#ACE226 - voltage asymmetry detection
0112/2///62683#ACE201 - kind of motor-starter
0112/2///62683#ACE202 - manual control
0112/2///62683#ACE203 - additional current transformer required
0112/2///62683#ACE209 - fault recording memory
0112/2///62683#ACE210 - test trip button
0112/2///62683#ACE211 - motor overload protection integrated
0112/2///62683#ACE212 - bypass circuit integrated
0112/2///62683#ACE214 - type of actuator
0112/2///62683#ACE251 - rated operating distance
0112/2///62683#ACE250 - effective operating distance
0112/2///62683#ACE253 - switching element function
0112/2///62683#ACE601 - kind of current
0112/2///62683#ACE254 - type of sensor output
0112/2///62683#ACE877 - number of wiring terminals
0112/2///62683#ACE440 - ambient air temperature
0112/2///62683#ACE241 - type of associated control or switching device
0112/2///62683#ACE249 - electric shock protection class
0112/2///62683#ACE260 - housing or body material
0112/2///62683#ACE261 - sensing face material
0112/2///62683#ACE256 - additional functions
0112/2///62683#ACE238 - degree of protection against mechanical impacts
0112/2///62683#ACE255 - mechanical durability
0112/2///62683#ACE649 - number of signal lights
0112/2///62683#ACE639 - sound signalling device
0112/2///62683#ACE640 - sound pressure level at 1 m
0112/2///62683#ACE647 - sound pressure level at 10 cm
0112/2///62683#ACE648 - audible signal type
0112/2///62683#ACE632 - possibility to be illuminated
0112/2///62683#ACE810 - diameter of the device
0112/2///62683#ACE646 - indicating tower colours combination
0112/2///62683#ACE637 - colour of the device body
0112/2///62683#ACE630 - colour of the lens
0112/2///62683#ACE240 - colour of the terminal assembly
0112/2///62683#ACE228 - disconnect means
0112/2///62683#ACE233 - integrated test socket
0112/2///62683#ACE217 - length of rope actuator
0112/2///62683#ACE252 - blind zone
0112/2///62683#ACE257 - sensing range
0112/2///62683#ACE258 - active optical signal
0112/2///62683#ACE267 - multi-turn
0112/2///62683#ACE268 - type of position encoding
0112/2///62683#ACE270 - distance resolution
0112/2///62683#ACE271 - steps per revolution
0112/2///62683#ACE272 - number of revolutions
0112/2///62683#ACE273 - measuring length
0112/2///62683#ACE274 - linear accuracy (of a measuring instrument)
0112/2///62683#ACE275 - shaft diameter
0112/2///62683#ACE279 - colour of the lamp
0112/2///62683#ACE280 - front shape of the support
0112/2///62683#ACE281 - colour of the accessory
0112/2///62683#ACE282 - height of the notch
0112/2///62683#ACE283 - width of the notch
0112/2///62683#ACE284 - through beam photoelectric proximity switch with its emitter
0112/2///62683#ACE286 - colour of the cover
0112/2///62683#ACE287 - material of the protective cover
0112/2///62683#ACE633 - type of lamp
0112/2///62683#ACE636 - marking of operating information
0112/2///62683#ACE650 - type of lamp socket
0112/2///62683#ACE232 - type of technology
0112/2///62683#ACE276 - time delay type
0112/2///62683#ACE277 - timer function
0112/2///62683#ACE288 - emergency stop
0112/2///62683#ACE229 - frequency of operating cycles
Properties tree:
Open all
|
Close all
In progress
Inherited properties:
SuperBlocks:
Is case of:
Imported properties:
Instance sharable:
false
Status level:
Standard
Is deprecated:
Published in:
IEC 62683DB
Published by:
IEC
Proposal date:
2022-09-08
Version initiation date:
2011-03-04
Version release date:
2022-09-08
Revision release date:
2022-09-08
Obsolete date:
Responsible Committee:
IEC/TC 121
Change request ID:
C00107
Version history:
Version history:
003-01 (2022-09-08 13:54:51 by BATCH 00000798)
standard
CLASSE
Code:
0112/2///62683#ACC012
Version:
003
Révision:
01
IRDI:
0112/2///62683#ACC012#003
Nom préféré:
Données techniques générales
Nom synonyme:
Nom codé:
Nom court:
Définition:
aspects techniques généraux de l'appareil
Note:
Remarque:
Traducteur:
IEC TC 121/WG 3
Version de traduction:
1
Date de traduction:
2022-07-12
Source de définition:
Dessin:
Class type:
ITEM_CLASS
Applicable documents:
Class value assignment:
Requisity of properties:
Superclasse:
0112/2///62683#ACC010
Classes supérieures:
0112/2///62683#ACC001 - Domaine des appareillages à basse tension
DET de classification:
Propriétés:
Propriétés:
0112/2///62683#ACE247 - degré de protection de la face avant
0112/2///62683#ACE248 - degré de protection des bornes
0112/2///62683#ACE204 - fonction de sectionnement
0112/2///62683#ACE243 - disposition pour le verrouillage
0112/2///62683#ACE239 - organe de commande motorisé
.....
0112/2///62683#ACE247 - degré de protection de la face avant
0112/2///62683#ACE248 - degré de protection des bornes
0112/2///62683#ACE204 - fonction de sectionnement
0112/2///62683#ACE243 - disposition pour le verrouillage
0112/2///62683#ACE239 - organe de commande motorisé
0112/2///62683#ACE219 - type de disjoncteur associé
0112/2///62683#ACE424 - courant assigné
0112/2///62683#ACE206 - utilisable en monophasé
0112/2///62683#ACE218 - degré de protection procuré par l'appareil
0112/2///62683#ACE234 - position de contact principal parfaitement visible en position ouverte
0112/2///62683#ACE236 - double ouverture du circuit
0112/2///62683#ACE215 - type de déclencheur contre les surintensités
0112/2///62683#ACE213 - classe de déclenchement
0112/2///62683#ACE207 - appareil autoalimenté
0112/2///62683#ACE208 - nature du réarmement du déclencheur de surcharge
0112/2///62683#ACE216 - capteur de courant intégré
0112/2///62683#ACE205 - délestage de charge
0112/2///62683#ACE220 - détection de défaut de mise à la masse/terre
0112/2///62683#ACE222 - détection de blocage
0112/2///62683#ACE221 - détection de calage
0112/2///62683#ACE223 - détection de maximum et/ou de minimum de courant
0112/2///62683#ACE224 - détection de maximum et/ou de minimum de tension
0112/2///62683#ACE225 - détection de déséquilibre de courant
0112/2///62683#ACE227 - détection d’inversion de phase
0112/2///62683#ACE226 - détection d'asymétrie de tension
0112/2///62683#ACE201 - nature du démarreur de moteur
0112/2///62683#ACE202 - commande manuelle
0112/2///62683#ACE203 - transformateur de courant supplémentaire requis
0112/2///62683#ACE209 - mémoire de défaut
0112/2///62683#ACE210 - bouton de déclenchement de test
0112/2///62683#ACE211 - protection intégrée contre la surcharge du moteur
0112/2///62683#ACE212 - circuit de dérivation intégré
0112/2///62683#ACE214 - type d’organe de commande
0112/2///62683#ACE251 - portée nominale
0112/2///62683#ACE250 - portée réelle
0112/2///62683#ACE253 - fonction de l'élément de commutation
0112/2///62683#ACE601 - nature du courant
0112/2///62683#ACE254 - type de sortie du capteur
0112/2///62683#ACE877 - nombre de bornes de raccordement
0112/2///62683#ACE440 - température ambiante
0112/2///62683#ACE241 - type d'appareil de commande ou de connexion associé
0112/2///62683#ACE249 - classe de protection contre les chocs électriques
0112/2///62683#ACE260 - matériau de l'enveloppe ou du corps
0112/2///62683#ACE261 - matériau de la face sensible
0112/2///62683#ACE256 - fonctions supplémentaires
0112/2///62683#ACE238 - degré de protection contre les impacts mécaniques
0112/2///62683#ACE255 - durabilité mécanique
0112/2///62683#ACE649 - nombre d'indicateurs lumineux
0112/2///62683#ACE639 - avertisseur sonore
0112/2///62683#ACE640 - niveau de pression acoustique à 1 m
0112/2///62683#ACE647 - niveau de pression acoustique à 10 cm
0112/2///62683#ACE648 - type de signal audible
0112/2///62683#ACE632 - aptitude à être éclairé
0112/2///62683#ACE810 - diamètre de l'appareil
0112/2///62683#ACE646 - combinaison de couleurs du cabochon
0112/2///62683#ACE637 - couleur du corps de l'appareil
0112/2///62683#ACE630 - couleur du cabochon
0112/2///62683#ACE240 - couleur de l'ensemble de bornes
0112/2///62683#ACE228 - moyen de sectionnement
0112/2///62683#ACE233 - douille de test intégrée
0112/2///62683#ACE217 - longueur de l'actionneur à corde
0112/2///62683#ACE252 - zone aveugle
0112/2///62683#ACE257 - domaine de détection
0112/2///62683#ACE258 - signal optique actif
0112/2///62683#ACE267 - multi-tour
0112/2///62683#ACE268 - type d'encodage de la position
0112/2///62683#ACE270 - résolution de distance
0112/2///62683#ACE271 - échelons par révolution
0112/2///62683#ACE272 - nombre de révolutions
0112/2///62683#ACE273 - longueur de mesurage
0112/2///62683#ACE274 - exactitude linéaire (d’un appareil de mesure)
0112/2///62683#ACE275 - diamètre d'axe
0112/2///62683#ACE279 - couleur de la lampe
0112/2///62683#ACE280 - forme avant du support
0112/2///62683#ACE281 - couleur de l'accessoire
0112/2///62683#ACE282 - hauteur de l'enfoncement
0112/2///62683#ACE283 - largeur de l'enfoncement
0112/2///62683#ACE284 - détecteur de proximité photoélectrique en barrage avec son émetteur
0112/2///62683#ACE286 - couleur du capuchon
0112/2///62683#ACE287 - matériau du capuchon de protection
0112/2///62683#ACE633 - type de lampe
0112/2///62683#ACE636 - marquage de l'information de fonctionnement
0112/2///62683#ACE650 - type de culot de lampe
0112/2///62683#ACE232 - type de technologie
0112/2///62683#ACE276 - type de temporisation
0112/2///62683#ACE277 - fonction de temporisation
0112/2///62683#ACE288 - arrêt d'urgence
0112/2///62683#ACE229 - fréquence de commutation
Propriétés:
Open all
|
Close all
In progress
Propriétés héritées:
Is case of:
Imported properties:
Instance sharable:
false
Statut:
Standard
Is deprecated:
Publié dans:
IEC 62683DB
Publié par:
IEC
Date de proposition:
2022-09-08
Version, date d'initialisation:
2011-03-04
Version, date de publication:
2022-09-08
Revision release date:
2022-09-08
Date d'obsolescence:
Responsible Committee:
IEC/TC 121
Change request ID:
C00107
Historique:
Historique:
003-01 (2022-09-08 13:54:51 by BATCH 00000798)
standard
KLASSE
Code:
0112/2///62683#ACC012
Version:
003
Revision:
01
IRDI:
0112/2///62683#ACC012#003
Bevorzugter Name:
Allgemeine technische Daten
Synonym:
Code:
Kurzbezeichnung:
Definition:
allgemeine technische Gesichtspunkte eines Geräts
Notiz:
Bemerkung:
Übersetzer:
DKE, Jürgen Schütz
Übersetzung, Revision:
1
Übersetzung, Revisionsdatum:
2017-06-15
Quelle der Definition:
Zeichnung:
Class type:
ITEM_CLASS
Applicable documents:
Class value assignment:
Requisity of properties:
Oberbegriff:
0112/2///62683#ACC010
Übergeordnete Klassen:
0112/2///62683#ACC001 - Bereich der Niederspannungs-schaltgeräte
Klassifizierendes Datenelement:
Merkmale:
Merkmale:
0112/2///62683#ACE247 - Schutzart der Vorderseite
0112/2///62683#ACE248 - Schutzart der Anschlüsse
0112/2///62683#ACE204 - Trennfunktion
0112/2///62683#ACE243 - Verriegelungsmöglichkeit
0112/2///62683#ACE239 - Motorantrieb
.....
0112/2///62683#ACE247 - Schutzart der Vorderseite
0112/2///62683#ACE248 - Schutzart der Anschlüsse
0112/2///62683#ACE204 - Trennfunktion
0112/2///62683#ACE243 - Verriegelungsmöglichkeit
0112/2///62683#ACE239 - Motorantrieb
0112/2///62683#ACE219 - Art des zugehörigen Leistungsschalters
0112/2///62683#ACE424 - Bemessungsstrom
0112/2///62683#ACE206 - Einphasenfähigkeit
0112/2///62683#ACE218 - Schutzart des Geräts
0112/2///62683#ACE234 - Hauptkontakt vollständig sichtbar in offener Position
0112/2///62683#ACE236 - Doppelunterbrecher
0112/2///62683#ACE215 - Art des Überstromauslösers
0112/2///62683#ACE213 - Auslöse¬klasse
0112/2///62683#ACE207 - eigenversorgt
0112/2///62683#ACE208 - Art der Rück-stellung des Überlast-auslösers
0112/2///62683#ACE216 - eingebauter Stromsensor
0112/2///62683#ACE205 - Lastabwurf
0112/2///62683#ACE220 - Erdschlusserkennung
0112/2///62683#ACE222 - Stauerkennung
0112/2///62683#ACE221 - Stillstandserkennung
0112/2///62683#ACE223 - Über- und/oder Unterstromerkennung
0112/2///62683#ACE224 - Über- und/oder Unterspannungserkennung
0112/2///62683#ACE225 - Stromasymmetrie-erkennung
0112/2///62683#ACE227 - Phasenumkehrerkennung
0112/2///62683#ACE226 - Spannungsasymmetrie-erkennung
0112/2///62683#ACE201 - Art des Motorstarters
0112/2///62683#ACE202 - Handbetätigung
0112/2///62683#ACE203 - zusätzliche Strom-umformung erforderlich
0112/2///62683#ACE209 - Fehler¬speicher
0112/2///62683#ACE210 - Test-Taste
0112/2///62683#ACE211 - integrierter Motorüberlast-schutz
0112/2///62683#ACE212 - integrierter Überbrückungsstromkreis
0112/2///62683#ACE214 - Art des Bedienteils
0112/2///62683#ACE251 - Bemessungsschaltabstand
0112/2///62683#ACE250 - Effektiver Schaltabstand
0112/2///62683#ACE253 - Funktion des Schaltelements
0112/2///62683#ACE601 - Stromart
0112/2///62683#ACE254 - Art des Ausgangs
0112/2///62683#ACE877 - Anzahl der Leitungs-anschlüsse
0112/2///62683#ACE440 - Umgebungstemperatur
0112/2///62683#ACE241 - Art des zugehörigen Schaltgeräts
0112/2///62683#ACE249 - Schutzklasse elektrischer Schlag
0112/2///62683#ACE260 - Gehäusewerkstoff
0112/2///62683#ACE261 - Werkstoff der aktiven Fläche
0112/2///62683#ACE256 - zusätzliche Funktionen
0112/2///62683#ACE238 - Schutzart des Gehäuses gegen mechanische Einwirkungen
0112/2///62683#ACE255 - mechanische Lebensdauer
0112/2///62683#ACE649 - Anzahl der Signalleuchten
0112/2///62683#ACE639 - akustischer Signalgeber
0112/2///62683#ACE640 - Schalldruckpegel bei 1 m
0112/2///62683#ACE647 - Schalldruckpegel bei 10 cm
0112/2///62683#ACE648 - Art des akustischen Signals
0112/2///62683#ACE632 - beleuchtbar
0112/2///62683#ACE810 - Durchmesser des Geräts
0112/2///62683#ACE646 - Farbkombination der Signalsäule
0112/2///62683#ACE637 - Farbe des Geräte-gehäuses
0112/2///62683#ACE630 - Farbe der Linse
0112/2///62683#ACE240 - Farbe der Klemmen-anordnung
0112/2///62683#ACE228 - Trennvorrichtung
0112/2///62683#ACE233 - integrierter Testsockel
0112/2///62683#ACE217 - Länge des Seiles
0112/2///62683#ACE252 - Blindzone
0112/2///62683#ACE257 - Erfassungsbereich
0112/2///62683#ACE258 - Aktives optisches Signal
0112/2///62683#ACE267 - mehrfach umdrehend
0112/2///62683#ACE268 - Art der Lagekodierung
0112/2///62683#ACE270 - Längenauflösung
0112/2///62683#ACE271 - Schritte pro Umdrehung
0112/2///62683#ACE272 - Anzahl der Umdrehungen
0112/2///62683#ACE273 - Messlänge
0112/2///62683#ACE274 - lineare Genauigkeit (eines Messgerätes)
0112/2///62683#ACE275 - Schaftdurchmesser
0112/2///62683#ACE279 - Farbe der Lampe
0112/2///62683#ACE280 - Frontgestaltung des Trägers
0112/2///62683#ACE281 - Farbe des Zubehörs
0112/2///62683#ACE282 - Höhe der Ausklinkung
0112/2///62683#ACE283 - Breite der Ausklinkung
0112/2///62683#ACE284 - Einweg-Lichtschranke mit Sender
0112/2///62683#ACE286 - Farbe der Schutzabdeckung
0112/2///62683#ACE287 - Material der Schutzabdeckung
0112/2///62683#ACE633 - Lampentyp
0112/2///62683#ACE636 - Bedienteilkennzeichnung
0112/2///62683#ACE650 - Art der Lampenfassung
0112/2///62683#ACE232 - Art der Technologie
0112/2///62683#ACE276 - Art der Zeitverzögerung
0112/2///62683#ACE277 - Timerfunktion
0112/2///62683#ACE288 - Not-Halt
0112/2///62683#ACE229 - Schaltfrequenz
Merkmale:
Open all
|
Close all
In progress
Übernommene Merkmale:
Is case of:
Imported properties:
Instance sharable:
false
Status:
Standard
Is deprecated:
Veröffentlicht in:
IEC 62683DB
Veröffentlicht von:
IEC
Datum des Vorschlags:
2022-09-08
Version, Veranlassungsdatum:
2011-03-04
Version, Freigabedatum:
2022-09-08
Revision release date:
2022-09-08
Gestrichen seit:
Responsible Committee:
IEC/TC 121
Change request ID:
C00107
Historie:
Historie:
003-01 (2022-09-08 13:54:51 by BATCH 00000798)
standard
分類(クラス)
識別コード:
0112/2///62683#ACC012
改訂版:
003
修正刷:
01
IRDI:
0112/2///62683#ACC012#003
推奨名:
別名:
コード化された名称:
略称:
定義:
注記:
備考:
翻訳者:
翻訳第 m 版:
翻訳版発行日:
定義出典:
図:
Class type:
ITEM_CLASS
Applicable documents:
Class value assignment:
Requisity of properties:
上位分類:
0112/2///62683#ACC010
上位クラス:
0112/2///62683#ACC001 - LV switchgear and controlgear domain
分類プロパティ:
プロパティ:
プロパティ:
0112/2///62683#ACE247 - degree of protection of front face
0112/2///62683#ACE248 - degree of protection of terminals
0112/2///62683#ACE204 - isolating function
0112/2///62683#ACE243 - provision for locking
0112/2///62683#ACE239 - motor-operator
.....
0112/2///62683#ACE247 - degree of protection of front face
0112/2///62683#ACE248 - degree of protection of terminals
0112/2///62683#ACE204 - isolating function
0112/2///62683#ACE243 - provision for locking
0112/2///62683#ACE239 - motor-operator
0112/2///62683#ACE219 - type of associated circuit-breaker
0112/2///62683#ACE424 - rated current
0112/2///62683#ACE206 - suitable for use in single phase
0112/2///62683#ACE218 - degree of protection of the device
0112/2///62683#ACE234 - main contact fully visible in open position
0112/2///62683#ACE236 - double opening of the circuit
0112/2///62683#ACE215 - type of over-current release
0112/2///62683#ACE213 - trip class
0112/2///62683#ACE207 - self-powered device
0112/2///62683#ACE208 - nature of the reset of the overload release
0112/2///62683#ACE216 - built-in current sensor
0112/2///62683#ACE205 - load shedding
0112/2///62683#ACE220 - ground/earth fault detection
0112/2///62683#ACE222 - jam detection
0112/2///62683#ACE221 - stall detection
0112/2///62683#ACE223 - over and/or under current detection
0112/2///62683#ACE224 - over and/or under voltage detection
0112/2///62683#ACE225 - current imbalance detection
0112/2///62683#ACE227 - phase reversal detection
0112/2///62683#ACE226 - voltage asymmetry detection
0112/2///62683#ACE201 - kind of motor-starter
0112/2///62683#ACE202 - manual control
0112/2///62683#ACE203 - additional current transformer required
0112/2///62683#ACE209 - fault recording memory
0112/2///62683#ACE210 - test trip button
0112/2///62683#ACE211 - motor overload protection integrated
0112/2///62683#ACE212 - bypass circuit integrated
0112/2///62683#ACE214 - type of actuator
0112/2///62683#ACE251 - rated operating distance
0112/2///62683#ACE250 - effective operating distance
0112/2///62683#ACE253 - switching element function
0112/2///62683#ACE601 - kind of current
0112/2///62683#ACE254 - type of sensor output
0112/2///62683#ACE877 - number of wiring terminals
0112/2///62683#ACE440 - ambient air temperature
0112/2///62683#ACE241 - type of associated control or switching device
0112/2///62683#ACE249 - electric shock protection class
0112/2///62683#ACE260 - housing or body material
0112/2///62683#ACE261 - sensing face material
0112/2///62683#ACE256 - additional functions
0112/2///62683#ACE238 - degree of protection against mechanical impacts
0112/2///62683#ACE255 - mechanical durability
0112/2///62683#ACE649 - number of signal lights
0112/2///62683#ACE639 - sound signalling device
0112/2///62683#ACE640 - sound pressure level at 1 m
0112/2///62683#ACE647 - sound pressure level at 10 cm
0112/2///62683#ACE648 - audible signal type
0112/2///62683#ACE632 - possibility to be illuminated
0112/2///62683#ACE810 - diameter of the device
0112/2///62683#ACE646 - indicating tower colours combination
0112/2///62683#ACE637 - colour of the device body
0112/2///62683#ACE630 - colour of the lens
0112/2///62683#ACE240 - colour of the terminal assembly
0112/2///62683#ACE228 - disconnect means
0112/2///62683#ACE233 - integrated test socket
0112/2///62683#ACE217 - length of rope actuator
0112/2///62683#ACE252 - blind zone
0112/2///62683#ACE257 - sensing range
0112/2///62683#ACE258 - active optical signal
0112/2///62683#ACE267 - multi-turn
0112/2///62683#ACE268 - type of position encoding
0112/2///62683#ACE270 - distance resolution
0112/2///62683#ACE271 - steps per revolution
0112/2///62683#ACE272 - number of revolutions
0112/2///62683#ACE273 - measuring length
0112/2///62683#ACE274 - linear accuracy (of a measuring instrument)
0112/2///62683#ACE275 - shaft diameter
0112/2///62683#ACE279 - colour of the lamp
0112/2///62683#ACE280 - front shape of the support
0112/2///62683#ACE281 - colour of the accessory
0112/2///62683#ACE282 - height of the notch
0112/2///62683#ACE283 - width of the notch
0112/2///62683#ACE284 - through beam photoelectric proximity switch with its emitter
0112/2///62683#ACE286 - colour of the cover
0112/2///62683#ACE287 - material of the protective cover
0112/2///62683#ACE633 - type of lamp
0112/2///62683#ACE636 - marking of operating information
0112/2///62683#ACE650 - type of lamp socket
0112/2///62683#ACE232 - type of technology
0112/2///62683#ACE276 - time delay type
0112/2///62683#ACE277 - timer function
0112/2///62683#ACE288 - emergency stop
0112/2///62683#ACE229 - frequency of operating cycles
プロパティ:
Open all
|
Close all
In progress
継承プロパティ:
Is case of:
Imported properties:
Instance sharable:
false
状態:
標準
Is deprecated:
公開:
IEC 62683DB
公開者:
IEC
提案日時:
2022-09-08
初版作成日:
2011-03-04
改訂版公開日:
2022-09-08
Revision release date:
2022-09-08
廃用期日:
Responsible Committee:
IEC/TC 121
Change request ID:
C00107
版改訂履歴:
版改訂履歴:
003-01 (2022-09-08 13:54:51 by BATCH 00000798)
standard
类
代码:
0112/2///62683#ACC012
版本号:
003
修订号:
01
IRDI:
0112/2///62683#ACC012#003
推荐名:
一般技术数据
同义名:
代码名:
短名:
定义:
电器技术方面的一般数据
注释:
备注:
Translator (to be translated in Chinese):
SAC, Li Hui
Translation revison (to be translated in Chinese):
1
Translation revision date (to be translated in Chinese):
2017-09-26
定义来源:
图:
类类型:
ITEM_CLASS
适用文档:
Class value assignment:
特性的必要性:
超类:
0112/2///62683#ACC010
上层类:
0112/2///62683#ACC001 - 低压开关设备和控制设备域
分类DET:
特性:
特性:
0112/2///62683#ACE247 - 正面防护等级
0112/2///62683#ACE248 - 接线端子防护等级
0112/2///62683#ACE204 - 隔离功能
0112/2///62683#ACE243 - 锁定装置
0112/2///62683#ACE239 - 电操装置
.....
0112/2///62683#ACE247 - 正面防护等级
0112/2///62683#ACE248 - 接线端子防护等级
0112/2///62683#ACE204 - 隔离功能
0112/2///62683#ACE243 - 锁定装置
0112/2///62683#ACE239 - 电操装置
0112/2///62683#ACE219 - 相关的断路器型号
0112/2///62683#ACE424 - 额定电流
0112/2///62683#ACE206 - 适用于单相
0112/2///62683#ACE218 - 电器防护等级
0112/2///62683#ACE234 - 主触头在断开状态下完全可见
0112/2///62683#ACE236 - 电路的双断点
0112/2///62683#ACE215 - 过电流脱扣器类型
0112/2///62683#ACE213 - 脱扣级别
0112/2///62683#ACE207 - 自供电电器
0112/2///62683#ACE208 - 过载脱扣器的复位性质
0112/2///62683#ACE216 - 嵌入式电流传感器
0112/2///62683#ACE205 - 甩负荷
0112/2///62683#ACE220 - 接地故障检测
0112/2///62683#ACE222 - 阻塞检测
0112/2///62683#ACE221 - 堵转检测
0112/2///62683#ACE223 - 过电流和/或欠电流检测
0112/2///62683#ACE224 - 过电压和/或欠电压检测
0112/2///62683#ACE225 - 电流不平衡检测
0112/2///62683#ACE227 - 反相检测
0112/2///62683#ACE226 - 电压不对称检测
0112/2///62683#ACE201 - 电动机起动器类型
0112/2///62683#ACE202 - 手动控制
0112/2///62683#ACE203 - 额外需要的电流互感器
0112/2///62683#ACE209 - 故障记录存储器
0112/2///62683#ACE210 - 试验脱扣按钮
0112/2///62683#ACE211 - 电动机内置过载保护
0112/2///62683#ACE212 - 内置的旁路电路
0112/2///62683#ACE214 - 操动器类型
0112/2///62683#ACE251 - 额定动作距离
0112/2///62683#ACE250 - 有效动作距离
0112/2///62683#ACE253 - 开关元件功能
0112/2///62683#ACE601 - 电流种类
0112/2///62683#ACE254 - 输出类型
0112/2///62683#ACE877 - 接线端子数量
0112/2///62683#ACE440 - 周围空气温度
0112/2///62683#ACE241 - 关联的开关电器类型
0112/2///62683#ACE249 - 电击防护等级
0112/2///62683#ACE260 - 外壳或基体材料
0112/2///62683#ACE261 - 感应面材料
0112/2///62683#ACE256 - 附加功能
0112/2///62683#ACE238 - 机械冲击防护等级
0112/2///62683#ACE255 - 机械耐久性
0112/2///62683#ACE649 - 信号灯数量
0112/2///62683#ACE639 - 发声信号装置
0112/2///62683#ACE640 - 声压水平,1m
0112/2///62683#ACE647 - 声压水平,10cm
0112/2///62683#ACE648 - 音频信号类型
0112/2///62683#ACE632 - 安装照明灯的可能性
0112/2///62683#ACE810 - 电器直径
0112/2///62683#ACE646 - 指示塔颜色组合
0112/2///62683#ACE637 - 电器本体颜色
0112/2///62683#ACE630 - 镜片颜色
0112/2///62683#ACE240 - 接线端子组件颜色
0112/2///62683#ACE228 - 断开方式
0112/2///62683#ACE233 - 内置的试验插座
0112/2///62683#ACE217 - 操动器长度
0112/2///62683#ACE252 - 盲区
0112/2///62683#ACE257 - 感应范围
0112/2///62683#ACE258 - 激活光信号
0112/2///62683#ACE267 - 多循环
0112/2///62683#ACE268 - 位置编码类型
0112/2///62683#ACE270 - 距离分辨率
0112/2///62683#ACE271 - 每转步数
0112/2///62683#ACE272 - 旋转数量
0112/2///62683#ACE273 - 测量长度
0112/2///62683#ACE274 - (测量仪器的)线性精度
0112/2///62683#ACE275 - 轴直径
0112/2///62683#ACE279 - 灯的颜色
0112/2///62683#ACE280 - 支架的正面形状
0112/2///62683#ACE281 - 附件颜色
0112/2///62683#ACE282 - 凹槽高度
0112/2///62683#ACE283 - 凹槽宽度
0112/2///62683#ACE284 - 带发射器的对射光电式接近开关
0112/2///62683#ACE286 - 外壳颜色
0112/2///62683#ACE287 - 保护罩材料
0112/2///62683#ACE633 - 灯的类型
0112/2///62683#ACE636 - 操动器标志
0112/2///62683#ACE650 - 灯座类型
0112/2///62683#ACE232 - 技术类型
0112/2///62683#ACE276 - 延时类型
0112/2///62683#ACE277 - 定时器功能
0112/2///62683#ACE288 - 紧急停止
0112/2///62683#ACE229 - 操作频率
特性树:
Open all
|
Close all
In progress
Inherited properties:
Is case of:
输入特性:
Instance sharable:
false
状态级别:
Standard (to be translated)
Is deprecated:
发布:
IEC 62683DB
发布者:
IEC
提议日期:
2022-09-08
版本生成日期:
2011-03-04
版本发布日期:
2022-09-08
修订发布日期:
2022-09-08
废止日期:
负责委员会:
IEC/TC 121
变更请求号:
C00107
版本历史:
版本历史:
003-01 (2022-09-08 13:54:51 by BATCH 00000798)
standard
Version history
Historique
Historie
版改訂履歴:
版本历史:
003-01 (2022-09-08 13:54:51 by BATCH 00000798)
standard
.....
002-01 (2022-06-27 15:45:36 by BATCH 00000795)
superseded
001-02 (2020-01-11 22:57:34 by BATCH 00000749)
superseded
001-01 (2022-06-15 19:23:52 by BATCH 00000794)
superseded
001-01 (2016-09-16 14:33:44 by BATCH 00000703)
superseded
Web page created
2025-04-25
Copyright ©
2025
IEC
, Geneva, Switzerland. All rights reserved