CLASS
Code:
0112/2///62683#ACG065
Version:
002
Revision:
01
IRDI:
0112/2///62683#ACG065#002
Preferred name:
Safety subsystem
Synonymous name:
device type 1, subsystem
Coded name:
Short name:
Definition:
entity of the top-level architectural design of a safety-related system where a dangerous failure of the subsystem results in dangerous failure of a safety function
Note:
Note 1 to entry: This differs from common language where “subsystem” may mean any sub-divided part of an entity, the term “subsystem” is used in this document within a strongly defined hierarchy of terminology: “subsystem” is the first level subdivision of a system. The parts resulting from further subdivision of a subsystem are called “subsystem elements”.
Note 2 to entry: A complete subsystem can be made up from a number of identifiable and separate subsystem elements.
Note 3 to entry: The subsystem specification includes its role in the safety function and its interface with the other subsystems of the SCS.
Note 4 to entry: One subsystem can be part of several safety functions, e.g. the same combination of contactors can be used to de-energise a motor either in the event of detection of a person in a danger zone or also in the event of opening an interlock guard.
Remark:
Definition source:
IEC 62061:2021, 3.2.4
Drawing:
Class type:
ITEM_CLASS
Applicable documents:
Class value assignment:
Requisity of properties:
Superclass:
0112/2///62683#ACG000
Higher level classes:
0112/2///62683#ACC010 - LV switchgear and controlgear blocks of properties
0112/2///62683#ACC001 - LV switchgear and controlgear domain
Classifying DET:
Properties:
Properties tree:
Open all
|
Close all
In progress
Inherited properties:
SuperBlocks:
0112/2///62683#ACC405 - Motor-starter combination
0112/2///62683#ACG070 - Safety device types
Is case of:
0112/2///62683#ACC077 - Safety integrity characteristics
0112/2///62683#ACC078 - Performance level characteristics
Imported properties:
0112/2///62683#ACE051 - safety integrity level
0112/2///62683#ACE052 - average frequency of a dangerous failure per hour
0112/2///62683#ACE058 - proof test interval
0112/2///62683#ACE060 - performance level
0112/2///62683#ACE063 - category
Instance sharable:
false
Status level:
Standard
Is deprecated:
Published in:
Published by:
IEC
Proposal date:
2025-09-25
Version initiation date:
2013-07-29
Version release date:
2025-09-26
Revision release date:
2025-09-26
Obsolete date:
Responsible Committee:
IEC/TC 121
Change request ID:
C00094
Version history:
Version history:
002-01 (2025-09-25 19:16:19 by BATCH 00000840)
standard
CLASSE
Code:
0112/2///62683#ACG065
Version:
002
Révision:
01
IRDI:
0112/2///62683#ACG065#002
Nom préféré:
Sous-système de sécurité
Nom synonyme:
dispositif de type 1, sous-système
Nom codé:
Nom court:
Définition:
entité de la conception architecturale générale d'un système relatif à la sécurité dans laquelle une défaillance dangereuse du sous-système conduit à une défaillance dangereuse d'une fonction de sécurité
Note:
Note 1 à l’article: Cette définition diffère du langage courant où le terme "sous-système" peut signifier une quelconque partie subdivisée d'une entité; le terme "sous-système" est utilisé dans le présent document dans une hiérarchie terminologique bien déterminée: le "sous-système" est le premier niveau de subdivision d'un système. Les parties résultant de subdivisions ultérieures d'un sous-système sont appelées "éléments de sous-système".
Note 2 à l’article: Un sous-système complet peut être constitué d'un certain nombre d'éléments de sous-système identifiables et séparés.
Note 3 à l’article: La spécification du sous-système inclut son rôle dans la fonction de sécurité et son interface avec les autres sous-systèmes du SCS.
Note 4 à l’article: Un sous-système peut faire partie de plusieurs fonctions de sécurité, par exemple, la même combinaison de contacteurs peut être utilisée pour couper l'alimentation d'un moteur soit en cas de détection d’une personne dans une zone de danger, soit également en cas d'ouverture d'un protecteur avec dispositif de verrouillage.
Remarque:
Traducteur:
IEC TC 121/WG 3
Version de traduction:
1
Date de traduction:
2021-10-05
Source de définition:
IEC 62061:2021, 3.2.4
Dessin:
Class type:
ITEM_CLASS
Applicable documents:
Class value assignment:
Requisity of properties:
Superclasse:
0112/2///62683#ACG000
Classes supérieures:
0112/2///62683#ACC010 - Blocs de propriétés des appareillages à basse tension
0112/2///62683#ACC001 - Domaine des appareillages à basse tension
DET de classification:
Propriétés:
Propriétés:
Open all
|
Close all
In progress
Propriétés héritées:
Is case of:
0112/2///62683#ACC077
0112/2///62683#ACC078
Imported properties:
0112/2///62683#ACE051
0112/2///62683#ACE052
0112/2///62683#ACE058
0112/2///62683#ACE060
0112/2///62683#ACE063
Instance sharable:
false
Statut:
Standard
Is deprecated:
Publié dans:
Publié par:
IEC
Date de proposition:
2025-09-25
Version, date d'initialisation:
2013-07-29
Version, date de publication:
2025-09-26
Revision release date:
2025-09-26
Date d'obsolescence:
Responsible Committee:
IEC/TC 121
Change request ID:
C00094
Historique:
Historique:
002-01 (2025-09-25 19:16:19 by BATCH 00000840)
standard
KLASSE
Code:
0112/2///62683#ACG065
Version:
002
Revision:
01
IRDI:
0112/2///62683#ACG065#002
Bevorzugter Name:
Sicherheitsteilsystem
Synonym:
Code:
Kurzbezeichnung:
Definition:
Einheit des Architekturentwurfs auf oberster Ebene eines sicherheitsbezogenen Systems, bei der ein gefahrbringender Ausfall des Teilsystems zu einem gefahrbringenden Ausfall einer Sicherheitsfunktion führt
Notiz:
Anmerkung 1 zum Begriff: Dies unterscheidet sich von der allgemeinen Sprache, wo „Teilsystem“ jeden unterteilten Teil einer Einheit bedeuten kann, der Begriff „Teilsystem“ wird in diesem Dokument innerhalb einer stark definierten Hierarchie der Terminologie verwendet: „Teilsystem“ ist die Unterteilung eines Systems auf oberster Ebene. Die Teile, die sich aus der weiteren Unterteilung eines Teilsystems ergeben, werden als „Teilsystem-Elemente“ bezeichnet.
Bemerkung:
Übersetzer:
DKE, Silvio Foertsch
Übersetzung, Revision:
1
Übersetzung, Revisionsdatum:
2025-09-01
Quelle der Definition:
IEC 62061:2021, 3.2.4
Zeichnung:
Class type:
ITEM_CLASS
Applicable documents:
Class value assignment:
Requisity of properties:
Oberbegriff:
0112/2///62683#ACG000
Übergeordnete Klassen:
0112/2///62683#ACC010 - Niederspannungsschaltgeräte Gruppen von Merkmalen
0112/2///62683#ACC001 - Bereich der Niederspannungs-schaltgeräte
Klassifizierendes Datenelement:
Merkmale:
Merkmale:
Open all
|
Close all
In progress
Übernommene Merkmale:
Is case of:
0112/2///62683#ACC077
0112/2///62683#ACC078
Imported properties:
0112/2///62683#ACE051
0112/2///62683#ACE052
0112/2///62683#ACE058
0112/2///62683#ACE060
0112/2///62683#ACE063
Instance sharable:
false
Status:
Standard
Is deprecated:
Veröffentlicht in:
Veröffentlicht von:
IEC
Datum des Vorschlags:
2025-09-25
Version, Veranlassungsdatum:
2013-07-29
Version, Freigabedatum:
2025-09-26
Revision release date:
2025-09-26
Gestrichen seit:
Responsible Committee:
IEC/TC 121
Change request ID:
C00094
Historie:
Historie:
002-01 (2025-09-25 19:16:19 by BATCH 00000840)
standard
分類(クラス)
識別コード:
0112/2///62683#ACG065
改訂版:
002
修正刷:
01
IRDI:
0112/2///62683#ACG065#002
推奨名:
別名:
コード化された名称:
略称:
定義:
注記:
備考:
翻訳者:
翻訳第 m 版:
翻訳版発行日:
定義出典:
IEC 62061:2021, 3.2.4
図:
Class type:
ITEM_CLASS
Applicable documents:
Class value assignment:
Requisity of properties:
上位分類:
0112/2///62683#ACG000
上位クラス:
0112/2///62683#ACC010 - LV switchgear and controlgear blocks of properties
0112/2///62683#ACC001 - LV switchgear and controlgear domain
分類プロパティ:
プロパティ:
プロパティ:
Open all
|
Close all
In progress
継承プロパティ:
Is case of:
0112/2///62683#ACC077
0112/2///62683#ACC078
Imported properties:
0112/2///62683#ACE051
0112/2///62683#ACE052
0112/2///62683#ACE058
0112/2///62683#ACE060
0112/2///62683#ACE063
Instance sharable:
false
状態:
標準
Is deprecated:
公開:
公開者:
IEC
提案日時:
2025-09-25
初版作成日:
2013-07-29
改訂版公開日:
2025-09-26
Revision release date:
2025-09-26
廃用期日:
Responsible Committee:
IEC/TC 121
Change request ID:
C00094
版改訂履歴:
版改訂履歴:
002-01 (2025-09-25 19:16:19 by BATCH 00000840)
standard
类
代码:
0112/2///62683#ACG065
版本号:
002
修订号:
01
IRDI:
0112/2///62683#ACG065#002
推荐名:
安全子系统
同义名:
代码名:
短名:
定义:
安全相关系统顶层架构设计的实体,其中子系统的危险失效导致安全功能的危险失效
注释:
注 1:这与日常用语不同,在日常用语中,“子系统” 可指一个实体的任何细分部分;而在本文档中,“子系统” 一词用于严格定义的术语层级体系中:“子系统” 是系统的第一层级细分。对子系统进一步细分后产生的部分称为 “子系统组件”。
注 2:一个完整的子系统可由若干可识别且相互独立的子系统组件构成。
注 3:子系统规范包括其在安全功能中所承担的角色,以及它与安全控制系统(SCS)中其他子系统的接口。
注 4:一个子系统可属于多个安全功能的组成部分,例如,同一组接触器既可用于在检测到危险区域内有人时切断电机电源,也可用于在联锁防护打开时切断电机电源。
备注:
Translator (to be translated in Chinese):
SAC,Jia Feng
Translation revison (to be translated in Chinese):
1
Translation revision date (to be translated in Chinese):
2025-08-05
定义来源:
IEC 62061:2021, 3.2.4
图:
类类型:
ITEM_CLASS
适用文档:
Class value assignment:
特性的必要性:
超类:
0112/2///62683#ACG000
上层类:
0112/2///62683#ACC010 - 低压开关设备和控制设备特性模块
0112/2///62683#ACC001 - 低压开关设备和控制设备域
分类DET:
特性:
特性树:
Open all
|
Close all
In progress
Inherited properties:
Is case of:
0112/2///62683#ACC077
0112/2///62683#ACC078
输入特性:
0112/2///62683#ACE051
0112/2///62683#ACE052
0112/2///62683#ACE058
0112/2///62683#ACE060
0112/2///62683#ACE063
Instance sharable:
false
状态级别:
Standard (to be translated)
Is deprecated:
发布:
发布者:
IEC
提议日期:
2025-09-25
版本生成日期:
2013-07-29
版本发布日期:
2025-09-26
修订发布日期:
2025-09-26
废止日期:
负责委员会:
IEC/TC 121
变更请求号:
C00094
版本历史:
版本历史:
002-01 (2025-09-25 19:16:19 by BATCH 00000840)
standard
Version history
Historique
Historie
版改訂履歴:
版本历史:
002-01 (2025-09-25 19:16:19 by BATCH 00000840)
standard
.....
001-03 (2024-09-19 22:57:05 by BATCH 00000811)
superseded
001-02 (2016-09-20 10:24:43 by BATCH 00000705)
superseded
001-01 (2016-09-16 14:33:46 by BATCH 00000703)
superseded
Web page created
2025-12-06
Copyright ©
2025
IEC
, Geneva, Switzerland. All rights reserved