PROPERTY
Code:
0112/2///61987#ABA558
Version:
009
Revision:
01
IRDI:
0112/2///61987#ABA558#009
Preferred name:
degree of protection (IP)
Synonymous name:
Symbol:
Synonymous symbol:
Short name:
Definition:
extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid foreign objects and/or ingress of water and verified by standardized test methods, expressed as an IP rating
Note:
Remark:
Primary unit:
Alternative units:
Level:
Data type:
ENUM_STRING_TYPE(0112/2///61360_7#CEA015)
Format:
Property constraint:
Definition source:
IEC 60529
Property data element type:
NON_DEPENDENT_P_DET
Drawing:
Formula in text:
Value list code:
0112/2///61360_7#CEA015
Value list:
DET class:
Applicable classes:
0112/2///61987#ABC045 - Transmitter body [2]
0112/2///61987#ABC174 - Connection head
0112/2///61987#ABC044 - Transmitter body [1]
0112/2///61987#ABC047 - Transmitter body [4]
0112/2///61987#ABC202 - Digital indicator
0112/2///61987#ABC195 - Dial indicator
0112/2///61987#ABC171 - Connection compartment
0112/2///61987#ABC157 - Clamp-on ultrasonic flowmeter
0112/2///61987#ABC302 - Insertion ultrasonic flowmeter
0112/2///61987#ABD480 - Dial indicator [2]
0112/2///61987#ABD850 - Digital indicator [2]
0112/2///61987#ABD848 - Dial indicator [3]
0112/2///61987#ABF268 - Cooling system
0112/2///61987#ABF261 - Fibre optics
0112/2///61987#ABF168 - Sonic probe
0112/2///61987#ABF468 - Modulator
0112/2///61987#ABF380 - Structural design of a connection head
0112/2///61987#ABF348 - Immersible probe or transmitter
0112/2///61987#ABF642 - Insertion ultrasonic density transmitter
0112/2///61987#ABH474 - Illumination
0112/2///61987#ABF375 - Transmitter/switch housing
0112/2///61987#ABE040 - Transmitter housing [3]
0112/2///61987#ABC049 - Transmitter housing [2]
0112/2///61987#ABE607 - Solenoid valve housing
0112/2///61987#ABC040 - Totalizer indicator [2]
0112/2///61987#ABC048 - Transmitter housing [1]
0112/2///61987#ABC655 - Totalizer indicator [1]
0112/2///61987#ABP025 - Device housing
Definition class:
0112/2///61987#ABA000
Code for unit:
Codes for alternative units:
Code for unit list:
Status level:
Standard
Is deprecated:
Published in:
IEC 61987
Published by:
IEC
Proposal date:
2025-08-04
Version initiation date:
2017-12-07
Version release date:
2025-08-04
Revision release date:
2025-08-04
Obsolete date:
Responsible Committee:
IEC/SC 65E
Conditions:
-
Change request ID:
C00185
Version history:
Version history:
009-01 (2025-08-04 15:30:51 by BATCH 00000849)
standard
PROPRIÉTÉ
Code:
0112/2///61987#ABA558
Version:
009
Révision:
01
IRDI:
0112/2///61987#ABA558#009
Nom préféré:
degré de protection (IP)
Nom synonyme:
Symbole:
Symbole synonyme:
Nom court:
Définition:
niveau de protection procuré par une enveloppe contre l'accès aux parties dangereuses, contre la pénétration de corps solides étrangers et/ou la pénétration d'eau et vérifié par des méthodes d’essai normalisées, exprimé en classe IP
Note:
Remarque:
Traducteur:
Mr. W. Hartmann
Version de traduction:
0
Date de traduction:
2013-04-21
Unité primaire:
Unités alternatives:
Niveau:
Type de données:
ENUM_STRING_TYPE(0112/2///61360_7#CEA015)
Format:
Property constraint:
Source de définition:
IEC 60529
Property data element type:
NON_DEPENDENT_P_DET
Dessin:
Formule:
Value list code:
0112/2///61360_7#CEA015
Liste de valeurs:
0112/2///61360_7#CTB278 - IP00
0112/2///61360_7#CTB279 - IP01
0112/2///61360_7#CTB280 - IP02
0112/2///61360_7#CTB281 - IP03
0112/2///61360_7#CTB282 - IP04
0112/2///61360_7#CTB283 - IP05
0112/2///61360_7#CTB284 - IP06
0112/2///61360_7#CTB285 - IP07
0112/2///61360_7#CTB286 - IP08
0112/2///61360_7#CTB287 - IP10
0112/2///61360_7#CTB288 - IP11
0112/2///61360_7#CTB289 - IP12
0112/2///61360_7#CTB290 - IP13
0112/2///61360_7#CTB291 - IP14
0112/2///61360_7#CTB292 - IP15
0112/2///61360_7#CTB293 - IP16
0112/2///61360_7#CTB294 - IP17
0112/2///61360_7#CTB295 - IP18
0112/2///61360_7#CTB296 - IP20
0112/2///61360_7#CTB297 - IP21
0112/2///61360_7#CTB298 - IP22
0112/2///61360_7#CTB299 - IP23
0112/2///61360_7#CTB300 - IP24
0112/2///61360_7#CTB301 - IP25
0112/2///61360_7#CTB302 - IP26
0112/2///61360_7#CTB303 - IP27
0112/2///61360_7#CTB304 - IP28
0112/2///61360_7#CTB305 - IP30
0112/2///61360_7#CTB306 - IP31
0112/2///61360_7#CTB307 - IP32
0112/2///61360_7#CTB308 - IP33
0112/2///61360_7#CTB309 - IP34
0112/2///61360_7#CTB310 - IP35
0112/2///61360_7#CTB311 - IP36
0112/2///61360_7#CTB312 - IP37
0112/2///61360_7#CTB313 - IP38
0112/2///61360_7#CTB314 - IP40
0112/2///61360_7#CTB315 - IP41
0112/2///61360_7#CTB316 - IP42
0112/2///61360_7#CTB317 - IP43
0112/2///61360_7#CTB318 - IP44
0112/2///61360_7#CTB319 - IP45
0112/2///61360_7#CTB320 - IP46
0112/2///61360_7#CTB321 - IP47
0112/2///61360_7#CTB322 - IP48
0112/2///61360_7#CTB323 - IP50
0112/2///61360_7#CTB324 - IP51
0112/2///61360_7#CTB325 - IP52
0112/2///61360_7#CTB326 - IP53
0112/2///61360_7#CTB327 - IP54
0112/2///61360_7#CTB328 - IP55
0112/2///61360_7#CTB329 - IP56
0112/2///61360_7#CTB330 - IP57
0112/2///61360_7#CTB331 - IP58
0112/2///61360_7#CTB332 - IP60
0112/2///61360_7#CTB333 - IP61
0112/2///61360_7#CTB334 - IP62
0112/2///61360_7#CTB335 - IP63
0112/2///61360_7#CTB336 - IP64
0112/2///61360_7#CTB337 - IP65
0112/2///61360_7#CTB338 - IP66
0112/2///61360_7#CTB339 - IP67
0112/2///61360_7#CTB340 - IP68
0112/2///61360_7#CTB341 - IP69
0112/2///61360_7#CTB342 - IPX1
0112/2///61360_7#CTB343 - IPX2
0112/2///61360_7#CTB344 - IPX3
0112/2///61360_7#CTB345 - IPX4
0112/2///61360_7#CTB346 - IPX5
0112/2///61360_7#CTB347 - IPX6
0112/2///61360_7#CTB348 - IPX7
0112/2///61360_7#CTB349 - IPX8
0112/2///61360_7#CTB350 - IP1X
0112/2///61360_7#CTB351 - IP2X
0112/2///61360_7#CTB352 - IP3X
0112/2///61360_7#CTB353 - IP4X
0112/2///61360_7#CTB354 - IP5X
0112/2///61360_7#CTB355 - IP6X
Classe DET:
Classes applicables:
0112/2///61987#ABC045 - Corps du transmetteur [2]
0112/2///61987#ABC174 - Tête de connexion
0112/2///61987#ABC044 - Corps du transmetteur [1]
0112/2///61987#ABC047 - Corps du transmetteur [4]
0112/2///61987#ABC202 - Indicateur numérique
0112/2///61987#ABC195 - Indicateur à cadran
0112/2///61987#ABC171 - Compartiment de raccordement
0112/2///61987#ABC157 - Débitmètre à ultrasons fixé par clamp
0112/2///61987#ABC302 - Débitmètre à ultrasons à insertion
0112/2///61987#ABD480 - Indicateur à cadran [2]
0112/2///61987#ABD850 - Indicateur numérique [2]
0112/2///61987#ABD848 - Indicateur à cadran [3]
0112/2///61987#ABF268 - Cooling system
0112/2///61987#ABF261 - Fibre optics
0112/2///61987#ABF168 - Sonic probe
0112/2///61987#ABF468 - Modulator
0112/2///61987#ABF380 - Structural design of a connection head
0112/2///61987#ABF348 - Immersible probe or transmitter
0112/2///61987#ABF642 - Débitmètre à ultrasons à insertion
0112/2///61987#ABH474 - Illumination
0112/2///61987#ABF375 - Transmitter/switch housing
0112/2///61987#ABE040 - Boîtier du transmetteur [3]
0112/2///61987#ABC049 - Boîtier du transmetteur [2]
0112/2///61987#ABE607 - Solenoid valve housing
0112/2///61987#ABC040 - Indicateur de totalisateur [2]
0112/2///61987#ABC048 - Boîtier du transmetteur [1]
0112/2///61987#ABC655 - Indicateur de totalisateur [1]
0112/2///61987#ABP025 - Device housing
Definition class:
0112/2///61987#ABA000
Code for unit:
Codes for alternative units:
Code for unit list:
Statut:
Standard
Is deprecated:
Publié dans:
IEC 61987
Publié par:
IEC
Date de proposition:
2025-08-04
Version, date d'initialisation:
2017-12-07
Version, date de publication:
2025-08-04
Revision release date:
2025-08-04
Date d'obsolescence:
Responsible Committee:
IEC/SC 65E
Conditions:
-
Change request ID:
C00185
Historique:
Historique:
009-01 (2025-08-04 15:30:51 by BATCH 00000849)
standard
MERKMAL
Code:
0112/2///61987#ABA558
Version:
009
Revision:
01
IRDI:
0112/2///61987#ABA558#009
Bevorzugter Name:
Schutzart (IP)
Synonym:
Symbol:
Synonymes Symbol:
Kurzbezeichnung:
Definition:
Ausmaß des durch ein Gehäuse gebotenen Schutzes vor Zugang zu gefährlichen Teilen und Eindringen von festen Fremdkörpern und/oder Wasser, der durch normierte Prüfverfahren bestätigt wurde, angegeben als IP-Einstufung
Notiz:
Bemerkung:
Übersetzer:
Mr. W. Hartmann
Übersetzung, Revision:
0
Übersetzung, Revisionsdatum:
2013-10-16
Empfohlene Einheit:
Alternative Einheit(en):
Ebene:
Datentyp:
ENUM_STRING_TYPE(0112/2///61360_7#CEA015)
Format:
Property constraint:
Quelle der Definition:
IEC 60529
Property data element type:
NON_DEPENDENT_P_DET
Zeichnung:
Formel:
Value list code:
0112/2///61360_7#CEA015
Werteliste:
0112/2///61360_7#CTB278 - IP00
0112/2///61360_7#CTB279 - IP01
0112/2///61360_7#CTB280 - IP02
0112/2///61360_7#CTB281 - IP03
0112/2///61360_7#CTB282 - IP04
0112/2///61360_7#CTB283 - IP05
0112/2///61360_7#CTB284 - IP06
0112/2///61360_7#CTB285 - IP07
0112/2///61360_7#CTB286 - IP08
0112/2///61360_7#CTB287 - IP10
0112/2///61360_7#CTB288 - IP11
0112/2///61360_7#CTB289 - IP12
0112/2///61360_7#CTB290 - IP13
0112/2///61360_7#CTB291 - IP14
0112/2///61360_7#CTB292 - IP15
0112/2///61360_7#CTB293 - IP16
0112/2///61360_7#CTB294 - IP17
0112/2///61360_7#CTB295 - IP18
0112/2///61360_7#CTB296 - IP20
0112/2///61360_7#CTB297 - IP21
0112/2///61360_7#CTB298 - IP22
0112/2///61360_7#CTB299 - IP23
0112/2///61360_7#CTB300 - IP24
0112/2///61360_7#CTB301 - IP25
0112/2///61360_7#CTB302 - IP26
0112/2///61360_7#CTB303 - IP27
0112/2///61360_7#CTB304 - IP28
0112/2///61360_7#CTB305 - IP30
0112/2///61360_7#CTB306 - IP31
0112/2///61360_7#CTB307 - IP32
0112/2///61360_7#CTB308 - IP33
0112/2///61360_7#CTB309 - IP34
0112/2///61360_7#CTB310 - IP35
0112/2///61360_7#CTB311 - IP36
0112/2///61360_7#CTB312 - IP37
0112/2///61360_7#CTB313 - IP38
0112/2///61360_7#CTB314 - IP40
0112/2///61360_7#CTB315 - IP41
0112/2///61360_7#CTB316 - IP42
0112/2///61360_7#CTB317 - IP43
0112/2///61360_7#CTB318 - IP44
0112/2///61360_7#CTB319 - IP45
0112/2///61360_7#CTB320 - IP46
0112/2///61360_7#CTB321 - IP47
0112/2///61360_7#CTB322 - IP48
0112/2///61360_7#CTB323 - IP50
0112/2///61360_7#CTB324 - IP51
0112/2///61360_7#CTB325 - IP52
0112/2///61360_7#CTB326 - IP53
0112/2///61360_7#CTB327 - IP54
0112/2///61360_7#CTB328 - IP55
0112/2///61360_7#CTB329 - IP56
0112/2///61360_7#CTB330 - IP57
0112/2///61360_7#CTB331 - IP58
0112/2///61360_7#CTB332 - IP60
0112/2///61360_7#CTB333 - IP61
0112/2///61360_7#CTB334 - IP62
0112/2///61360_7#CTB335 - IP63
0112/2///61360_7#CTB336 - IP64
0112/2///61360_7#CTB337 - IP65
0112/2///61360_7#CTB338 - IP66
0112/2///61360_7#CTB339 - IP67
0112/2///61360_7#CTB340 - IP68
0112/2///61360_7#CTB341 - IP69
0112/2///61360_7#CTB342 - IPX1
0112/2///61360_7#CTB343 - IPX2
0112/2///61360_7#CTB344 - IPX3
0112/2///61360_7#CTB345 - IPX4
0112/2///61360_7#CTB346 - IPX5
0112/2///61360_7#CTB347 - IPX6
0112/2///61360_7#CTB348 - IPX7
0112/2///61360_7#CTB349 - IPX8
0112/2///61360_7#CTB350 - IP1X
0112/2///61360_7#CTB351 - IP2X
0112/2///61360_7#CTB352 - IP3X
0112/2///61360_7#CTB353 - IP4X
0112/2///61360_7#CTB354 - IP5X
0112/2///61360_7#CTB355 - IP6X
Geltungsbereich:
Anwendbare Klassen:
0112/2///61987#ABC045 - Messumformerkörper
0112/2///61987#ABC174 - Anschlusskopf
0112/2///61987#ABC044 - Messumformerkörper
0112/2///61987#ABC047 - Messumformerkörper
0112/2///61987#ABC202 - Digitalanzeiger
0112/2///61987#ABC195 - Zeigerinstrument
0112/2///61987#ABC171 - Anschlussgehäuse
0112/2///61987#ABC157 - Aufschnall-Ultraschalldurchflussmesser
0112/2///61987#ABC302 - Sonden-Ultraschalldurchflussmesser
0112/2///61987#ABD480 - Zeigerinstrument [2]
0112/2///61987#ABD850 - Digitalanzeiger [2]
0112/2///61987#ABD848 - Zeigerinstrument
0112/2///61987#ABF268 - Kühlsystem
0112/2///61987#ABF261 - Lichtleiter-Optik
0112/2///61987#ABF168 - Schallsonde
0112/2///61987#ABF468 - Modulator
0112/2///61987#ABF380 - Konstruktiver Aufbau eines Anschlusskopfs
0112/2///61987#ABF348 - Eintauchsonde oder -Messumformer
0112/2///61987#ABF642 - Sonden-Ultraschalldichtemessgerät
0112/2///61987#ABH474 - Beleuchtung
0112/2///61987#ABF375 - Messumformer-/Schaltergehäuse
0112/2///61987#ABE040 - Messumformergehäuse [3]
0112/2///61987#ABC049 - Messumformergehäuse [2]
0112/2///61987#ABE607 - Magnetventil-Gehäuse
0112/2///61987#ABC040 - Summenzähler [2]
0112/2///61987#ABC048 - Messumformergehäuse [1]
0112/2///61987#ABC655 - Summenzähler [1]
0112/2///61987#ABP025 - Gerätegehäuse
Definition class:
0112/2///61987#ABA000
Code for unit:
Codes for alternative units:
Code for unit list:
Status:
Standard
Is deprecated:
Veröffentlicht in:
IEC 61987
Veröffentlicht von:
IEC
Datum des Vorschlags:
2025-08-04
Version, Veranlassungsdatum:
2017-12-07
Version, Freigabedatum:
2025-08-04
Revision release date:
2025-08-04
Gestrichen seit:
Responsible Committee:
IEC/SC 65E
Bedingung(en):
-
Change request ID:
C00185
Historie:
Historie:
009-01 (2025-08-04 15:30:51 by BATCH 00000849)
standard
プロパティ(属性)
識別コード:
0112/2///61987#ABA558
改訂版:
009
修正刷:
01
IRDI:
0112/2///61987#ABA558#009
推奨名:
別名:
記号:
同義記号:
略称:
定義:
注記:
備考:
翻訳者:
翻訳第 m 版:
翻訳版発行日:
主用単位:
代替単位系:
レベル:
データ型:
ENUM_STRING_TYPE(0112/2///61360_7#CEA015)
形式:
Property constraint:
定義出典:
IEC 60529
Property data element type:
NON_DEPENDENT_P_DET
図:
数式:
Value list code:
0112/2///61360_7#CEA015
値リスト:
0112/2///61360_7#CTB278 - IP00
0112/2///61360_7#CTB279 - IP01
0112/2///61360_7#CTB280 - IP02
0112/2///61360_7#CTB281 - IP03
0112/2///61360_7#CTB282 - IP04
0112/2///61360_7#CTB283 - IP05
0112/2///61360_7#CTB284 - IP06
0112/2///61360_7#CTB285 - IP07
0112/2///61360_7#CTB286 - IP08
0112/2///61360_7#CTB287 - IP10
0112/2///61360_7#CTB288 - IP11
0112/2///61360_7#CTB289 - IP12
0112/2///61360_7#CTB290 - IP13
0112/2///61360_7#CTB291 - IP14
0112/2///61360_7#CTB292 - IP15
0112/2///61360_7#CTB293 - IP16
0112/2///61360_7#CTB294 - IP17
0112/2///61360_7#CTB295 - IP18
0112/2///61360_7#CTB296 - IP20
0112/2///61360_7#CTB297 - IP21
0112/2///61360_7#CTB298 - IP22
0112/2///61360_7#CTB299 - IP23
0112/2///61360_7#CTB300 - IP24
0112/2///61360_7#CTB301 - IP25
0112/2///61360_7#CTB302 - IP26
0112/2///61360_7#CTB303 - IP27
0112/2///61360_7#CTB304 - IP28
0112/2///61360_7#CTB305 - IP30
0112/2///61360_7#CTB306 - IP31
0112/2///61360_7#CTB307 - IP32
0112/2///61360_7#CTB308 - IP33
0112/2///61360_7#CTB309 - IP34
0112/2///61360_7#CTB310 - IP35
0112/2///61360_7#CTB311 - IP36
0112/2///61360_7#CTB312 - IP37
0112/2///61360_7#CTB313 - IP38
0112/2///61360_7#CTB314 - IP40
0112/2///61360_7#CTB315 - IP41
0112/2///61360_7#CTB316 - IP42
0112/2///61360_7#CTB317 - IP43
0112/2///61360_7#CTB318 - IP44
0112/2///61360_7#CTB319 - IP45
0112/2///61360_7#CTB320 - IP46
0112/2///61360_7#CTB321 - IP47
0112/2///61360_7#CTB322 - IP48
0112/2///61360_7#CTB323 - IP50
0112/2///61360_7#CTB324 - IP51
0112/2///61360_7#CTB325 - IP52
0112/2///61360_7#CTB326 - IP53
0112/2///61360_7#CTB327 - IP54
0112/2///61360_7#CTB328 - IP55
0112/2///61360_7#CTB329 - IP56
0112/2///61360_7#CTB330 - IP57
0112/2///61360_7#CTB331 - IP58
0112/2///61360_7#CTB332 - IP60
0112/2///61360_7#CTB333 - IP61
0112/2///61360_7#CTB334 - IP62
0112/2///61360_7#CTB335 - IP63
0112/2///61360_7#CTB336 - IP64
0112/2///61360_7#CTB337 - IP65
0112/2///61360_7#CTB338 - IP66
0112/2///61360_7#CTB339 - IP67
0112/2///61360_7#CTB340 - IP68
0112/2///61360_7#CTB341 - IP69
0112/2///61360_7#CTB342 - IPX1
0112/2///61360_7#CTB343 - IPX2
0112/2///61360_7#CTB344 - IPX3
0112/2///61360_7#CTB345 - IPX4
0112/2///61360_7#CTB346 - IPX5
0112/2///61360_7#CTB347 - IPX6
0112/2///61360_7#CTB348 - IPX7
0112/2///61360_7#CTB349 - IPX8
0112/2///61360_7#CTB350 - IP1X
0112/2///61360_7#CTB351 - IP2X
0112/2///61360_7#CTB352 - IP3X
0112/2///61360_7#CTB353 - IP4X
0112/2///61360_7#CTB354 - IP5X
0112/2///61360_7#CTB355 - IP6X
ISO 31 プロパティ分類 :
実効クラス:
0112/2///61987#ABC045 - Transmitter body [2]
0112/2///61987#ABC174 - Connection head
0112/2///61987#ABC044 - Transmitter body [1]
0112/2///61987#ABC047 - Transmitter body [4]
0112/2///61987#ABC202 - Digital indicator
0112/2///61987#ABC195 - Dial indicator
0112/2///61987#ABC171 - Connection compartment
0112/2///61987#ABC157 - Clamp-on ultrasonic flowmeter
0112/2///61987#ABC302 - Insertion ultrasonic flowmeter
0112/2///61987#ABD480 - Dial indicator [2]
0112/2///61987#ABD850 - Digital indicator [2]
0112/2///61987#ABD848 - Dial indicator [3]
0112/2///61987#ABF268 - Cooling system
0112/2///61987#ABF261 - Fibre optics
0112/2///61987#ABF168 - Sonic probe
0112/2///61987#ABF468 - Modulator
0112/2///61987#ABF380 - Structural design of a connection head
0112/2///61987#ABF348 - Immersible probe or transmitter
0112/2///61987#ABF642 - Insertion ultrasonic density transmitter
0112/2///61987#ABH474 - Illumination
0112/2///61987#ABF375 - Transmitter/switch housing
0112/2///61987#ABE040 - Transmitter housing [3]
0112/2///61987#ABC049 - Transmitter housing [2]
0112/2///61987#ABE607 - Solenoid valve housing
0112/2///61987#ABC040 - Totalizer indicator [2]
0112/2///61987#ABC048 - Transmitter housing [1]
0112/2///61987#ABC655 - Totalizer indicator [1]
0112/2///61987#ABP025 - Device housing
Definition class:
0112/2///61987#ABA000
Code for unit:
Codes for alternative units:
Code for unit list:
状態:
標準
Is deprecated:
公開:
IEC 61987
公開者:
IEC
提案日時:
2025-08-04
初版作成日:
2017-12-07
改訂版公開日:
2025-08-04
Revision release date:
2025-08-04
廃用期日:
Responsible Committee:
IEC/SC 65E
条件:
-
Change request ID:
C00185
版改訂履歴:
版改訂履歴:
009-01 (2025-08-04 15:30:51 by BATCH 00000849)
standard
PROPERTY
代码:
0112/2///61987#ABA558
版本号:
009
修订号:
01
IRDI:
0112/2///61987#ABA558#009
推荐名:
同义名:
符号:
同义符号:
短名:
定义:
注释:
备注:
Translator (to be translated in Chinese):
Translation revison (to be translated in Chinese):
Translation revision date (to be translated in Chinese):
基本单位:
替代单位:
层:
Data type:
ENUM_STRING_TYPE(0112/2///61360_7#CEA015)
格式:
Property constraint:
定义来源:
IEC 60529
特性数据元素类型:
NON_DEPENDENT_P_DET
图:
公式:
取值列表代码:
0112/2///61360_7#CEA015
取值列表:
0112/2///61360_7#CTB278 - IP00 - IP00
0112/2///61360_7#CTB279 - IP01 - IP01
0112/2///61360_7#CTB280 - IP02 - IP02
0112/2///61360_7#CTB281 - IP03 - IP03
0112/2///61360_7#CTB282 - IP04 - IP04
0112/2///61360_7#CTB283 - IP05 - IP05
0112/2///61360_7#CTB284 - IP06 - IP06
0112/2///61360_7#CTB285 - IP07 - IP07
0112/2///61360_7#CTB286 - IP08 - IP08
0112/2///61360_7#CTB287 - IP10 - IP10
0112/2///61360_7#CTB288 - IP11 - IP11
0112/2///61360_7#CTB289 - IP12 - IP12
0112/2///61360_7#CTB290 - IP13 - IP13
0112/2///61360_7#CTB291 - IP14 - IP14
0112/2///61360_7#CTB292 - IP15 - IP15
0112/2///61360_7#CTB293 - IP16 - IP16
0112/2///61360_7#CTB294 - IP17 - IP17
0112/2///61360_7#CTB295 - IP18 - IP18
0112/2///61360_7#CTB296 - IP20 - IP20
0112/2///61360_7#CTB297 - IP21 - IP21
0112/2///61360_7#CTB298 - IP22 - IP22
0112/2///61360_7#CTB299 - IP23 - IP23
0112/2///61360_7#CTB300 - IP24 - IP24
0112/2///61360_7#CTB301 - IP25 - IP25
0112/2///61360_7#CTB302 - IP26 - IP26
0112/2///61360_7#CTB303 - IP27 - IP27
0112/2///61360_7#CTB304 - IP28 - IP28
0112/2///61360_7#CTB305 - IP30 - IP30
0112/2///61360_7#CTB306 - IP31 - IP31
0112/2///61360_7#CTB307 - IP32 - IP32
0112/2///61360_7#CTB308 - IP33 - IP33
0112/2///61360_7#CTB309 - IP34 - IP34
0112/2///61360_7#CTB310 - IP35 - IP35
0112/2///61360_7#CTB311 - IP36 - IP36
0112/2///61360_7#CTB312 - IP37 - IP37
0112/2///61360_7#CTB313 - IP38 - IP38
0112/2///61360_7#CTB314 - IP40 - IP40
0112/2///61360_7#CTB315 - IP41 - IP41
0112/2///61360_7#CTB316 - IP42 - IP42
0112/2///61360_7#CTB317 - IP43 - IP43
0112/2///61360_7#CTB318 - IP44 - IP44
0112/2///61360_7#CTB319 - IP45 - IP45
0112/2///61360_7#CTB320 - IP46 - IP46
0112/2///61360_7#CTB321 - IP47 - IP47
0112/2///61360_7#CTB322 - IP48 - IP48
0112/2///61360_7#CTB323 - IP50 - IP50
0112/2///61360_7#CTB324 - IP51 - IP51
0112/2///61360_7#CTB325 - IP52 - IP52
0112/2///61360_7#CTB326 - IP53 - IP53
0112/2///61360_7#CTB327 - IP54 - IP54
0112/2///61360_7#CTB328 - IP55 - IP55
0112/2///61360_7#CTB329 - IP56 - IP56
0112/2///61360_7#CTB330 - IP57 - IP57
0112/2///61360_7#CTB331 - IP58 - IP58
0112/2///61360_7#CTB332 - IP60 - IP60
0112/2///61360_7#CTB333 - IP61 - IP61
0112/2///61360_7#CTB334 - IP62 - IP62
0112/2///61360_7#CTB335 - IP63 - IP63
0112/2///61360_7#CTB336 - IP64 - IP64
0112/2///61360_7#CTB337 - IP65 - IP65
0112/2///61360_7#CTB338 - IP66 - IP66
0112/2///61360_7#CTB339 - IP67 - IP67
0112/2///61360_7#CTB340 - IP68 - IP68
0112/2///61360_7#CTB341 - IP69 - IP69
0112/2///61360_7#CTB342 - IPX1 - IPX1
0112/2///61360_7#CTB343 - IPX2 - IPX2
0112/2///61360_7#CTB344 - IPX3 - IPX3
0112/2///61360_7#CTB345 - IPX4 - IPX4
0112/2///61360_7#CTB346 - IPX5 - IPX5
0112/2///61360_7#CTB347 - IPX6 - IPX6
0112/2///61360_7#CTB348 - IPX7 - IPX7
0112/2///61360_7#CTB349 - IPX8 - IPX8
0112/2///61360_7#CTB350 - IP1X - IP1X
0112/2///61360_7#CTB351 - IP2X - IP2X
0112/2///61360_7#CTB352 - IP3X - IP3X
0112/2///61360_7#CTB353 - IP4X - IP4X
0112/2///61360_7#CTB354 - IP5X - IP5X
0112/2///61360_7#CTB355 - IP6X - IP6X
DET类:
适用类:
0112/2///61987#ABC045 - Transmitter body [2]
0112/2///61987#ABC174 - Connection head
0112/2///61987#ABC044 - Transmitter body [1]
0112/2///61987#ABC047 - Transmitter body [4]
0112/2///61987#ABC202 - Digital indicator
0112/2///61987#ABC195 - Dial indicator
0112/2///61987#ABC171 - Connection compartment
0112/2///61987#ABC157 - Clamp-on ultrasonic flowmeter
0112/2///61987#ABC302 - Insertion ultrasonic flowmeter
0112/2///61987#ABD480 - Dial indicator [2]
0112/2///61987#ABD850 - Digital indicator [2]
0112/2///61987#ABD848 - Dial indicator [3]
0112/2///61987#ABF268 - Cooling system
0112/2///61987#ABF261 - Fibre optics
0112/2///61987#ABF168 - Sonic probe
0112/2///61987#ABF468 - Modulator
0112/2///61987#ABF380 - Structural design of a connection head
0112/2///61987#ABF348 - Immersible probe or transmitter
0112/2///61987#ABF642 - Insertion ultrasonic density transmitter
0112/2///61987#ABH474 - Illumination
0112/2///61987#ABF375 - Transmitter/switch housing
0112/2///61987#ABE040 - Transmitter housing [3]
0112/2///61987#ABC049 - Transmitter housing [2]
0112/2///61987#ABE607 - Solenoid valve housing
0112/2///61987#ABC040 - Totalizer indicator [2]
0112/2///61987#ABC048 - Transmitter housing [1]
0112/2///61987#ABC655 - Totalizer indicator [1]
0112/2///61987#ABP025 - Device housing
定义类:
0112/2///61987#ABA000
单位代码:
替代单位代码:
单位列表代码:
状态级别:
Standard (to be translated)
Is deprecated:
发布:
IEC 61987
发布者:
IEC
提议日期:
2025-08-04
版本生成日期:
2017-12-07
版本发布日期:
2025-08-04
修订发布日期:
2025-08-04
废止日期:
负责委员会:
IEC/SC 65E
条件:
-
变更请求号:
C00185
版本历史:
版本历史:
009-01 (2025-08-04 15:30:51 by BATCH 00000849)
standard
Version history
Historique
Historie
版改訂履歴:
版本历史:
009-01 (2025-08-04 15:30:51 by BATCH 00000849)
standard
.....
008-01 (2024-08-13 13:58:17 by BATCH 00000832)
superseded
007-01 (2020-02-24 11:58:26 by BATCH 00000774)
superseded
006-01 (2018-03-28 07:26:37 by BATCH 00000762)
superseded
005-01 (2018-03-20 12:23:31 by BATCH 00000755)
superseded
004-01 (2017-03-01 14:51:18 by BATCH 00000732)
superseded
003-01 (2016-03-22 09:54:36 by BATCH 00000714)
superseded
002-01 (2016-05-02 12:36:06 by BATCH 00000716)
superseded
001-02 (2014-06-18 13:41:30 by BATCH 00000702)
superseded
001-01 (2014-04-08 17:25:29 by BATCH 00000699)
superseded
Web page created
2025-12-05
Copyright ©
2025
IEC
, Geneva, Switzerland. All rights reserved