Commission Electrotechnique Internationale
International Electrotechnical Commission
Международная Электротехническая Комиссия
Queries, comments, suggestions? Please
contact us
.
Area:
604: Generation, transmission and distribution of electricity - Operation
Index language:
Arabic
English
French
German
Italian
Polish
Portuguese
Spanish
Swedish
Section 604-01: Quality of supply
604-01-01
supply (of electricity)
604-01-02
distribution undertaking
604-01-03
consumer
604-01-04
point of supply
604-01-05
quality of supply
604-01-06
frequency deviation
604-01-07
frequency stability
604-01-08
frequency drift
604-01-09
frequency reduction
604-01-10
source of harmonic voltage
604-01-11
source of harmonic current
604-01-12
harmonic resonance
604-01-13
subsynchronous resonance
604-01-14
ferro-resonance
604-01-15
voltage stability
604-01-16
supply voltage
604-01-17
voltage deviation
604-01-18
line voltage drop
604-01-19
voltage fluctuation
604-01-20
cyclic voltage variation
604-01-21
voltage reduction
604-01-22
voltage collapse
604-01-23
loss of voltage
604-01-24
voltage recovery
604-01-25
voltage dip
604-01-26
flicker voltage range
604-01-27
equivalent flicker voltage fluctuation
604-01-28
flickermeter
604-01-29
voltage unbalance
604-01-30
unbalance factor
604-01-31
balancing of a distribution network
604-01-32
continuity of supply
604-01-33
(supply) continuity criterion
604-01-34
supply disconnection
604-01-35
load recovery
604-01-36
cut-off load
604-01-37
energy not supplied
604-01-38
(load weighted) equivalent interruption duration (annual, monthly)
604-01-39
cost of kWh not supplied
604-01-40
centralized telecontrol (of loads)
604-01-41
deferrable load
604-01-42
series injection of a centralized telecontrol signal
604-01-43
shunt injection of a centralized telecontrol signal
604-01-44
voltage depression
604-01-45
voltage instability
Section 604-02: Faults
604-02-01
fault (in electric power system)
604-02-02
insulation fault
604-02-03
incident
604-02-04
system incident
604-02-05
maloperation
604-02-06
unwanted operation
604-02-07
failure to operate
604-02-08
damage fault
604-02-09
non-damage fault
604-02-10
permanent fault
604-02-11
transient fault
604-02-12
self-extinguishing fault
604-02-13
self-extinguishing current limit
604-02-14
intermittent fault
604-02-15
resistive fault
604-02-16
dead short
604-02-17
line fault
604-02-18
busbar fault
604-02-19
phase-to-earth fault
604-02-20
phase-to-phase fault (clear of earth)
604-02-21
two-phase-to-earth fault
604-02-22
double faults
604-02-23
multiple faults
604-02-24
three-phase fault
604-02-25
developing fault
604-02-26
turn-to-turn fault
604-02-27
interwinding fault
604-02-28
fault clearance
604-02-29
fault clearance time
604-02-30
closing
604-02-31
opening
604-02-32
automatic reclosing
604-02-33
high speed automatic reclosing
604-02-34
delayed automatic reclosing
604-02-35
successful reclosing
604-02-36
unsuccessful reclosing
604-02-37
single shot reclosing
604-02-38
automatic multiple shot reclosing
604-02-39
final tripping
604-02-40
load transfer
604-02-41
fault location
604-02-42
fault locator
604-02-43
disturbance recorder
Section 604-03: Over voltages and insulation co-ordination
604-03-01
highest voltage for equipment
604-03-02
external insulation
604-03-03
internal insulation
604-03-04
self-restoring insulation
604-03-05
non-self-restoring insulation
604-03-06
earth fault factor
604-03-07
insulation of equipment
604-03-08
insulation co-ordination
604-03-09
overvoltage (in a system)
604-03-10
phase-to-earth overvoltage per unit
604-03-11
phase-to-phase overvoltage per unit
604-03-12
temporary overvoltage
604-03-13
transient overvoltage
604-03-14
voltage impulse
604-03-15
voltage surge
604-03-16
front of a voltage impulse
604-03-17
tail of a voltage impulse
604-03-18
lightning impulse
604-03-19
virtual front duration (of a lightning impulse)
604-03-20
switching impulse
604-03-21
time to crest (of a switching impulse)
604-03-22
time to half value (of an impulse)
604-03-23
full lightning impulse
604-03-24
chopped lightning impulse
604-03-25
time to chopping
604-03-26
impulse chopped on the front
604-03-27
impulse chopped on the tail
604-03-28
impulse generator
604-03-31
internal overvoltage
604-03-32
external overvoltage
604-03-33
direct lightning strike
604-03-34
indirect lightning strike
604-03-35
accidental voltage transfer
604-03-36
resonant overvoltage
604-03-37
breakdown
604-03-38
disruptive discharge
604-03-39
back flashover
604-03-40
power frequency withstand voltage
604-03-41
withstand voltage
604-03-42
statistical impulse withstand voltage
604-03-43
fifty per cent disruptive discharge voltage
604-03-44
dielectric dry test
604-03-45
dielectric wet test
604-03-46
artificial pollution test
604-03-47
insulation level
604-03-48
overhead earth wire
604-03-49
(protective) spark gap
604-03-50
lightning conductor
604-03-51
lightning arrester
604-03-52
discharge current (of an arrester)
604-03-53
residual voltage (of an arrester)
604-03-54
non-linear resistor type arrester
604-03-55
expulsion type arrester
604-03-56
lightning impulse protective level (of a protective device)
604-03-57
switching impulse protective level (of a protective device)
604-03-58
protection ratio against lightning impulses
604-03-59
protection ratio against switching impulses
604-03-60
clearance
604-03-61
creepage distance
604-03-62
insulating material
Section 604-04: Safety
604-04-01
to earth (equipment, an installation or a system)
604-04-02
earthing system
604-04-03
earth electrode
604-04-04
separate earth electrodes
604-04-05
remote earth
604-04-06
earth conductor
604-04-07
earthing network
604-04-08
earth terminal
604-04-09
earth rod
604-04-10
earth plate
604-04-11
earth strip
604-04-12
operational earthing
604-04-13
earthing for work
604-04-14
stray currents
604-04-15
cathodic protection
604-04-16
electric shock
604-04-17
electrocution
604-04-18
electric burn
604-04-19
electric mark
604-04-20
electro-ophthalmia
604-04-21
fibrillating current
604-04-22
freezing current
604-04-23
releasing current
604-04-24
threshold current
604-04-25
live working
604-04-26
safe clearance working
604-04-27
insulated gloves method
604-04-28
bare hand method
604-04-29
insulated tool
604-04-30
insulating tool
604-04-31
working pole
604-04-32
hand pole
604-04-33
universal tool attachment
604-04-34
support pole
604-04-35
protective cover
604-04-36
conductive clothing
604-04-37
aerial lift device with insulating arm
Section 604-05: Electromagnetic interference and noise in telecommunication systems
604-05-01
exposure (of a telecommunication line to a power line)
604-05-02
parallelism
604-05-03
oblique exposure
604-05-04
crossing
604-05-05
screening factor
604-05-06
high reliability power line (according to CCITT)
Copyright
©
IEC
2010. All Rights Reserved.