Queries, comments, suggestions? Please contact us.



Area: 603: Generation, transmission and distribution of electricity - Power systems planning and management           Index language:

Hide details for [<u>Section 603-01: Power system planning</u>]Section 603-01: Power system planning
603-01-01
power system planning
603-01-02
load density
603-01-03
load centre
603-01-04
load forecast
603-01-05
generation mix forecast
603-01-06
transmission capacity of a link
603-01-07
short-circuit current capability
Hide details for [<u>Section 603-02: Network calculation</u>]Section 603-02: Network calculation
603-02-01
network calculation
603-02-02
system state variables
603-02-03
system parameters
603-02-04
network topology
603-02-05
topological diagram of a network
603-02-06
steady state of a system
603-02-07
transient state of a system
603-02-08
load flow calculation
603-02-09
state estimation
603-02-10
short-circuit calculation
603-02-11
equivalent network
603-02-12
network conversion
603-02-13
star-polygon conversion
603-02-14
delta-wye conversion
603-02-15
active network
603-02-16
passive network
603-02-17
passive equivalent network
603-02-18
balanced state of a polyphase network
603-02-19
unbalanced state of a polyphase network
603-02-20
series impedance
603-02-21
shunt admittance
603-02-22
fault impedance
603-02-23
surge impedance of a line
603-02-24
natural load of a line
603-02-25
fault current
603-02-26
short-circuit current
603-02-27
current in the fault
603-02-28
current in the short circuit
603-02-29
reference node
603-02-30
infinite bus
603-02-31
balancing bus
603-02-32
slack bus
603-02-33
load bus
603-02-34
voltage controlled bus
603-02-35
passive bus
603-02-36
incidence matrix
603-02-37
bus admittance matrix
603-02-38
bus impedance matrix
603-02-39
mesh impedance matrix
603-02-40
redundancy factor
Hide details for [<u>Section 603-03: Stability</u>]Section 603-03: Stability
603-03-01
power system stability
603-03-02
steady state stability of a power system
603-03-03
transient stability of a power system
603-03-04
conditional stability of a power system
603-03-05
inherent stability of a power system
603-03-06
internal angle of an alternator
603-03-07
angle of deviation between two e.m.f.'s
603-03-08
swing curve
603-03-09
load stability
603-03-10
stability limit of a system state variable
603-03-11
stability margin of a system state variable
603-03-12
stability zone
603-03-13
synchronous operation of a machine
603-03-14
synchronous operation of a system
603-03-15
asynchronous operation of a synchronous machine
603-03-16
out-of-step operation
603-03-17
hunting of interconnected synchronous machines
603-03-18
synchronization of two systems
603-03-19
self-synchronization
603-03-20
synchronism restoration
603-03-21
power system instability
603-03-22
steady-state instability (of a power system)
603-03-23
transient instability (of a power system)
603-03-24
oscillatory instability (of a power system)
Hide details for [<u>Section 603-04: Power system control</u>]Section 603-04: Power system control
603-04-01
power system management
603-04-02
generation schedule
603-04-03
system demand control
603-04-04
primary control (of the speed of generating sets)
603-04-05
secondary control (of active power in a system)
603-04-06
power/frequency control
603-04-07
adaptive control
603-04-08
droop of a set
603-04-09
droop of a system
603-04-10
regulating energy of a system
603-04-11
controlling power range
603-04-12
synchronous time
603-04-13
deviation of synchronous time
603-04-14
steady-state load characteristic
603-04-15
transient load characteristic
603-04-16
power-regulation coefficient of load
603-04-17
scheduled operation (of a generating set)
603-04-18
(secondary) power control operation, (of a generating set)
603-04-19
control range, (of a generating set)
603-04-20
base load set
603-04-21
controllable set
603-04-22
peak load set
603-04-23
voltage control
603-04-24
voltage map
603-04-25
in-phase (voltage) control
603-04-26
quadrature (voltage) control
603-04-27
reactive-power voltage control
603-04-28
reactive power compensation
603-04-29
series compensation
603-04-30
shunt compensation
603-04-31
islanding
603-04-32
load shedding
603-04-33
isolated operation
603-04-34
separate network operation
603-04-35
parallel operation
603-04-36
interconnected operation
603-04-37
ring operation of a part of a network
603-04-38
radial operation (of a part of a network)
603-04-39
ring closing
603-04-40
ring opening
603-04-41
interruptible load
603-04-42
controllable load
603-04-43
loss of load
603-04-44
power shortfall
603-04-45
energy shortfall
603-04-46
island (in a power system)
Hide details for [<u>Section 603-05: Power system reliability</u>]Section 603-05: Power system reliability
603-05-01
reliability of an item
603-05-02
service reliability
603-05-03
service security
603-05-04
availability
603-05-05
outage
603-05-06
failure
603-05-07
planned outage
603-05-08
forced outage
603-05-09
availability factor
603-05-10
unavailability factor
603-05-11
interruption of supply
603-05-12
primary failure
603-05-13
secondary failure
603-05-14
common mode failure
603-05-15
operating duration
603-05-16
stand-by duration
603-05-17
up duration
603-05-18
down duration
603-05-19
planned-outage duration
603-05-20
maintenance duration
603-05-21
forced-outage duration
603-05-22
repair duration
603-05-23
interruption duration
603-05-24
outage rate
Hide details for [<u>Section 603-06: Economic optimization</u>]Section 603-06: Economic optimization
603-06-01
management forecast of a system
603-06-02
optimum load
603-06-03
economic loading schedule
603-06-04
power losses
603-06-05
energy losses
603-06-06
transmission losses
603-06-07
distribution losses
603-06-08
utilization time of power losses
603-06-09
(energy) loss factor
603-06-10
present value of cost losses
603-06-11
supply-interruption costs
603-06-12
reinforcement of a system
603-06-13
"target" system


Copyright © IEC 2024. All Rights Reserved.