Commission Electrotechnique Internationale
International Electrotechnical Commission
Международная Электротехническая Комиссия

 

Queries, comments, suggestions? Please contact us.



Area: 394: Nuclear instrumentation - Instruments, systems, equipment and detectors           Index language:

Hide details for [<u>Section 394-21: Radiation measuring apparatus – General</u>]Section 394-21: Radiation measuring apparatus – General
394-21-01
nuclear instrumentation
394-21-02
functionnal unit
394-21-03
crate (for nuclear instrumentation)
394-21-04
bin
394-21-05
Nuclear Instrumentation Module
394-21-06
module
394-21-07
Computer Automated Measurement and Control
394-21-08
CAMAC crate-controller
394-21-09
bus
394-21-10
FASTBUS
394-21-11
radiation detection assembly
394-21-12
measuring channel
Hide details for [<u>Section 394-22: Radiation measuring apparatus</u>]Section 394-22: Radiation measuring apparatus
394-22-01
radiation meter
394-22-02
probe (of a radiation meter)
394-22-03
(radiation) monitor
394-22-04
(radiation) alarm system
394-22-05
(radiation) spectrometer
394-22-06
mass spectrometer
394-22-07
nuclear magnetic resonance spectrometer
394-22-08
dosimeter
Hide details for [<u>Section 394-23: Apparatus for processing, storage and display of the information</u>]Section 394-23: Apparatus for processing, storage and display of the information
394-23-01
scaler
394-23-02
electrometer
394-23-03
ratemeter
394-23-04
spectrum stabilizer
394-23-07
amplitude-to-time converter
394-23-08
time-to-amplitude converter
394-23-09
time-to digital converter
394-23-10
discriminator
394-23-11
single channel analyser
394-23-12
multi channel analyser
394-23-13
coincidence circuit
394-23-14
(pulse) selector
394-23-15
pulse shaper
394-23-16
biased amplifier
Hide details for [<u>Section 394-24: Radiation detectors – General</u>]Section 394-24: Radiation detectors – General
394-24-01
radiation detector
394-24-02
linear detector
394-24-03
non-linear detector
394-24-04
self-powered detector
394-24-05
neutron thermopile
394-24-06
2π/4π radiation detector
394-24-07
chemical detector
394-24-08
calorimetric detector
394-24-09
track detector
394-24-10
dip detector
394-24-11
well-type detector
394-24-12
track etched detector
394-24-13
nuclear emulsion
394-24-14
etch pit
Hide details for [<u>Section 394-25: Ionization chambers</u>]Section 394-25: Ionization chambers
394-25-01
ionization detector
394-25-02
ionization chamber
394-25-03
pulse ionization detector
394-25-04
pulse ionization chamber
394-25-05
electron collection pulse chamber
394-25-06
ion collection pulse chamber
394-25-07
grid ionization chamber
394-25-08
boron trifluoride ionization chamber
394-25-09
boron-lined ionization chamber
394-25-10
fission ionization chamber
394-25-11
integrating ionization chamber
394-25-12
current ionization chamber
394-25-13
free air ionization chamber
394-25-14
Bragg-Gray cavity ionization chamber
394-25-15
air-equivalent ionization chamber
394-25-16
liquid wall ionization chamber
394-25-17
wall-less ionization chamber
394-25-18
tissue-equivalent ionization chamber
394-25-19
differential ionization chamber
394-25-20
compensated ionization chamber
394-25-21
extrapolation ionization chamber
394-25-22
recoil nuclei ionization chamber
394-25-23
thimble ionization chamber
394-25-24
well-type ionization chamber
394-25-25
Ionization chamber with internal gas source
394-25-26
capacitive ionization chamber
394-25-27
2π/4π ionization chamber
394-25-28
electret ionization chamber
394-25-29
gas-flow ionization chamber
394-25-30
gas-flow detector
394-25-31
proton recoil ionization chamber
Hide details for [<u>Section 394-26: Track and spark chambers</u>]Section 394-26: Track and spark chambers
394-26-01
track chamber
394-26-02
bubble chamber
394-26-03
cloud chamber
394-26-04
diffusion chamber
394-26-05
Wilson cloud chamber
394-26-06
spark chamber
394-26-07
charge emission detector
Hide details for [<u>Section 394-27: Scintillation and luminescence detectors</u>]Section 394-27: Scintillation and luminescence detectors
394-27-01
scintillation detector
394-27-02
air-equivalent scintillation detector
394-27-03
tissue equivalent scintillation detector
394-27-04
thermoluminescent detector
394-27-05
photoluminescent detector
Hide details for [<u>Section 394-28: Semiconductor radiation detectors, their components and characteristics</u>]Section 394-28: Semiconductor radiation detectors, their components and characteristics
394-28-01
semiconductor detector
394-28-02
surface barrier detector
394-28-03
diffused junction detector
394-28-04
implanted junction detector
394-28-05
compensated semiconductor detector
394-28-06
lithium drifted semiconductor detector
394-28-07
amplifying semiconductor detector
394-28-08
transmission semiconductor detector
394-28-09
differential dE/dx semiconductor detector
394-28-10
totally depleted semiconductor detector
394-28-11
boron coated semiconductor detector
394-28-12
lithium coated semiconductor detector
394-28-13
fission semiconductor detector
394-28-14
high purity semiconductor detector
394-28-15
radiation compensated semiconductor detector
394-28-16
converter (for neutron detectors)
394-28-17
multi-junction semiconductor detector
394-28-18
planar semiconductor detector
394-28-19
coaxial semiconductor detector
394-28-20
guard-ring semiconductor detector
394-28-21
mosaic semiconductor detector
394-28-22
position-sensitive semiconductor detector
394-28-23
junction
394-28-24
PN junction
394-28-25
forward direction (of a PN junction)
394-28-26
reverse direction (of a PN junction)
394-28-27
breakdown (of a reverse biased PN junction)
394-28-28
avalanche breakdown (of a junction)
394-28-29
avalanche voltage
394-28-30
depletion layer (of a semiconductor detector)
394-28-31
total depletion voltage (of a semiconductor detector)
394-28-32
charge collection time (of a semiconductor detector)
394-28-33
semiconductor
394-28-34
intrinsic semiconductor
394-28-35
compensated semiconductor
394-28-36
extrinsic semiconductor
394-28-37
N-type semiconductor
394-28-38
P-type semiconductor
Hide details for [<u>Section 394-29: Counter tubes</u>]Section 394-29: Counter tubes
394-29-01
counter tube
394-29-02
proportional counter tube
394-29-03
boron trifluoride proportional counter tube
394-29-04
boron lined counter tube
394-29-05
helium counter tube
394-29-06
recoil nuclei counter tube
394-29-07
Geiger-Müller counter tube
394-29-08
self-quenched counter tube
394-29-09
thin wall counter tube
394-29-10
window counter tube
394-29-11
fission counter tube
394-29-12
dip counter tube
394-29-13
liquid counter tube
394-29-14
external cathode counter tube
394-29-15
corona counter tube
394-29-16
spark counter
394-29-17
Cherenkov detector
Hide details for [<u>Section 394-30: Components of radiation detectors</u>]Section 394-30: Components of radiation detectors
394-30-01
scintillating material
394-30-02
activator
394-30-03
wavelength shifter
394-30-04
collecting electrode
394-30-05
guard ring
394-30-06
thermoluminescent material
394-30-07
neutron sensitive material
394-30-08
quenching circuit
394-30-09
quenching gas
394-30-10
scintillator
394-30-11
electron multiplier
394-30-12
photomultiplier tube
394-30-13
windowless photomultiplier tube
394-30-14
dynode
394-30-15
light guide
394-30-16
window (of a detector)
394-30-17
surface-barrier contact
394-30-18
photodiode
Hide details for [<u>Section 394-31: Radiation protection instrumentation – Fluence, exposure, absorbed dose, or dose equivaleSection 394-31: Radiation protection instrumentation – Fluence, exposure, absorbed dose, or dose equivalent meters and ratemeters
394-31-01
radiation protection instrumentation
394-31-02
thermoluminescence dosimeter
394-31-03
thermoluminescence dosimetry system
394-31-04
reader for thermoluminescence dosimeter
394-31-05
particle fluence ratemeter
394-31-06
particle fluence rate monitor
394-31-07
particle fluence rate indicator
394-31-08
(absorbed) dose ratemeter
394-31-09
dose equivalent meter
394-31-10
dose equivalent ratemeter
394-31-11
personal dosimeter
394-31-12
dosimeter charger
394-31-13
dosimeter reader
394-31-14
photoluminescence dosimeter
394-31-15
reader for photoluminescence dosimeter
394-31-16
film dosimeter
394-31-17
albedo neutron dosimeter
394-31-18
dose rate monitor
394-31-19
dose rate warning assembly
394-31-20
environmental dosimeter
Hide details for [<u>Section 394-32: Contamination or activity measuring equipment or assemblies</u>]Section 394-32: Contamination or activity measuring equipment or assemblies
394-32-01
radioactive surface contamination meter
394-32-02
radioactive surface contamination monitor
394-32-03
beta-gamma doorway monitor
394-32-04
radioactive air contamination meter
394-32-05
radioactive air contamination monitor
394-32-06
radioactive air contamination indicator
394-32-07
air sampler
394-32-08
airborne dust or particle monitor
394-32-09
total (potential) alpha energy meter (detector)
394-32-10
radioactive aerosol meter
394-32-11
radioactive iodine meter/monitor
394-32-12
liquid radioactivity meter/monitor
394-32-13
evaporated liquid sample activity meter
394-32-14
gas radioactivity meter
394-32-15
radon content meter/monitor
394-32-16
tissue activity detector
394-32-17
whole body counter
394-32-18
radio-bioassay meter
394-32-19
criticality accident monitor
394-32-20
accident monitor
394-32-21
noble gas effluent monitor for accident conditions
394-32-22
liquid effluent monitor
Hide details for [<u>Section 394-33: Systems, equipment and assemblies for operation and safety of nuclear reactors</u>]Section 394-33: Systems, equipment and assemblies for operation and safety of nuclear reactors
394-33-01
nuclear reactor instrumentation
394-33-02
safety group (of a nuclear reactor)
394-33-03
power measuring assembly based on activation
394-33-04
period meter
394-33-05
reactivity meter
394-33-06
failed fuel element monitor
394-33-07
fuel channel activity comparator
394-33-08
electrostatic collector failed fuel element monitor
394-33-09
Cherenkov effect failed fuel element monitor
394-33-10
fission product separator failed fuel element monitor
394-33-11
delayed neutron failed fuel element monitor
394-33-12
failed fuel element indicator
394-33-13
fault tolerance
394-33-14
graceful degradation
394-33-15
software life cycle
394-33-16
software modularity
394-33-17
software verification
394-33-18
design verification
394-33-19
man machine interface
394-33-20
auxiliary operating control system
394-33-21
displays (in control room)
394-33-22
operator support system
394-33-23
public address system (for nuclear facilities)
394-33-24
visual display unit
394-33-25
safety-related instrumentation and control systems
394-33-26
item important to safety
394-33-27
configuration management
Hide details for [<u>Section 394-34: Warning, safety and protection systems and assemblies of a nuclear reactor</u>]Section 394-34: Warning, safety and protection systems and assemblies of a nuclear reactor
394-34-01
safety system (of a nuclear reactor)
394-34-02
safety member
394-34-03
safety system support features
394-34-08
protection system (of a nuclear reactor)
394-34-09
safety actuation system
394-34-12
interlock system important for safety
394-34-13
safety alarm system
394-34-14
actuation device
394-34-15
audible warning system
394-34-16
code of (best) practice
394-34-17
functionality
394-34-18
interlock functions
394-34-19
emergency shutdown rod
394-34-20
alarm system
Hide details for [<u>Section 394-35: Various measuring assemblies and equipment used in a nuclear reactor</u>]Section 394-35: Various measuring assemblies and equipment used in a nuclear reactor
394-35-01
cladding temperature computer
394-35-02
gas-flow neutron fluence rate measuring assembly
394-35-03
thermal power measuring assembly
394-35-04
in-core neutron fluence rate mapping system
394-35-05
coolant gross activity monitor
394-35-06
transfer function (of a nuclear reactor)
394-35-07
transfer function meter (of a nuclear reactor)
394-35-08
heavy water content meter
394-35-09
electric penetration assembly (of a nuclear reactor)
394-35-10
in-core temperature measuring sensor
394-35-11
in-core temperature measuring system
394-35-12
noise diagnostic system (of a nuclear reactor)
394-35-13
safety parameter display system
394-35-14
Campbell system for neutron monitoring
394-35-15
shim member
394-35-18
control member drive mechanism (of a nuclear reactor)
394-35-19
control member
394-35-20
control rod
394-35-21
booster rod
394-35-22
grey rod
394-35-23
black rod
Hide details for [<u>Section 394-37: Radiation measuring equipment and assemblies for industrial use</u>]Section 394-37: Radiation measuring equipment and assemblies for industrial use
394-37-01
radiation gauge
394-37-02
thickness gauge
394-37-03
transmission measurement system
394-37-04
back-scatter measurement system
394-37-05
X ray fluorescence measurement system
394-37-06
density gauge
394-37-07
transmission density gauge
394-37-08
back-scatter soil density gauge
394-37-09
transmission soil density gauge
394-37-10
level gauge
394-37-11
material presence gauge
394-37-12
level following gauge
394-37-13
carbon to hydrogen ratio gauge
Hide details for [<u>Section 394-38: Characteristics of radiation detectors</u>]Section 394-38: Characteristics of radiation detectors
394-38-01
scintillation
394-38-02
scintillation duration
394-38-03
scintillation rise time
394-38-04
scintillation fall time
394-38-05
scintillation decay time
394-38-06
emission spectrum (of a scintillator)
394-38-07
photon emission curve (of a scintillator)
394-38-08
energy conversion efficiency (of a scintillator)
394-38-09
conversion quantum efficiency (of a photocathode)
394-38-10
spectral response curve (of a photocathode)
394-38-11
photocathode sensitivity
394-38-12
transit time (in a photomultiplier tube)
394-38-13
transit time jitter (in a photomultiplier tube)
394-38-14
dark current (in a photomultiplier tube)
394-38-15
gain (of a photomultiplier tube)
394-38-16
collection efficiency (of a photomultiplier tube)
394-38-17
detector efficiency
394-38-18
detection efficiency
394-38-19
total absorption detector efficiency
394-38-20
total absorption detection efficiency
394-38-21
selectivity (of a detector)
394-38-22
sensitive volume (of a detector)
394-38-23
wall effect
394-38-24
ionization current
394-38-25
residual current (of a detector)
394-38-26
leakage current
394-38-27
ion collection time
394-38-28
electron collection time
394-38-29
burst (in an ionization chamber)
394-38-30
saturation current (in an ionization chamber)
394-38-31
saturation voltage (in an ionization chamber)
394-38-32
saturation curve (of a current ionization chamber)
394-38-33
Bragg-Gray cavity
394-38-34
compensation factor (of a compensated ionization chamber)
394-38-35
compensation ratio (of a compensated ionization chamber)
394-38-36
gas multiplication
394-38-37
Townsend avalanche
394-38-38
critical field (of a counter)
394-38-39
gas multiplication factor
394-38-40
end effect (of a counter)
394-38-41
proportional region
394-38-42
region of limited proportionality
394-38-43
Geiger-Müller region
394-38-44
Geiger-Müller threshold
394-38-45
overvoltage (of a Geiger-Müller counter)
394-38-46
characteristic curve (of any radiation detector)
394-38-47
plateau
394-38-48
plateau relative slope
394-38-49
quenching
394-38-50
dead time (in a detector operating in pulse mode)
394-38-51
ionization track
394-38-52
sensitive time , (of a track chamber)
394-38-53
discriminator curve
394-38-54
fading
394-38-55
Compton continuum
394-38-56
photoelectric peak
394-38-57
total absorption peak
394-38-58
maximum acceptable irradiation rate (of a detector)
394-38-59
phosphorescence
394-38-60
fluorescence
394-38-61
(radio) thermoluminescence
394-38-62
light sensitivity (of a photomultiplier)
394-38-63
spectral sensitivity (of a photomultiplier)
394-38-64
light sensitivity non-uniformity (of a photomultiplier)
394-38-65
discharge noise (of a corona counter tube)
394-38-66
spectral peak
394-38-67
bias (of a radiation detector)
394-38-68
discrimination threshold (of a radiation detector)
394-38-69
spectrum (of a pulse height distribution)
394-38-70
energy window
394-38-71
dose albedo
394-38-72
differential dose albedo
Hide details for [<u>Section 394-39: Characteristics of radiation measuring assemblies</u>]Section 394-39: Characteristics of radiation measuring assemblies
394-39-01
count
394-39-02
spurious count
394-39-03
count rate
394-39-04
time-of-flight (of a particle)
394-39-05
mobility (of a charged particle)
394-39-06
scaling factor (of a scaler)
394-39-07
sensitivity (of a measuring assembly)
394-39-08
background level (of a measuring assembly)
394-39-09
response time (of a measuring assembly)
394-39-10
settling time (of a measuring assembly)
394-39-11
rise time (of a measuring assembly)
394-39-12
energy resolution (of a radiation spectrometer)
394-39-13
counting loss (of a counting assembly)
394-39-14
pile-up (in a counting assembly)
394-39-15
pulse coincidence
394-39-16
true coincidence
394-39-17
random coincidence
394-39-18
coincidence resolving time
394-39-19
anticoincidence
394-39-20
response threshold (to pulses)
394-39-21
resolving time
394-39-22
resolving time correction
394-39-23
recovery time
394-39-24
latent time
394-39-25
peak-to-total ratio
394-39-26
escape peaks
394-39-27
equivalent noise referred to input (of a linear amplifier)
394-39-28
clipping time
394-39-29
real time (in case of multi-channel analyser)
394-39-30
pole-zero cancellation
394-39-31
live time
394-39-32
peak-to-Compton ratio
394-39-33
dead time (for analyser)
394-39-34
sampling time (of a detection assembly)
394-39-35
warm-up time
394-39-36
fall time , (of a measuring assembly)
394-39-38
individual channel width
394-39-39
conversion time (of an analogue-to-digital converter)
394-39-40
restoration time
394-39-41
calibration curve
394-39-42
rated range
394-39-43
rated range of use
394-39-44
equivalent window thickness (of a detector system)
394-39-45
sampling collection efficiency
394-39-46
admissible count rate
394-39-47
alarm set point
394-39-48
random variation
394-39-49
Compton stripping
394-39-50
signal saturation
394-39-51
dead band
394-39-52
pulse rate
Hide details for [<u>Section 394-40: Tests, errors of measurements and various parameters concerning nuclear instrumentation</uSection 394-40: Tests, errors of measurements and various parameters concerning nuclear instrumentation
394-40-01
test
394-40-02
type test
394-40-03
routine test
394-40-04
commissioning test
394-40-05
acceptance test
394-40-06
life test
394-40-07
periodic test
394-40-08
maintenance test
394-40-09
seismic qualification testing
394-40-10
conventionally true value of a quantity
394-40-11
relative error
394-40-12
intrinsic error
394-40-13
error (of measurement)
394-40-14
coefficient of variation
394-40-15
reference point
394-40-16
effective range of measurement
394-40-17
dynamic range
394-40-18
check source
394-40-19
reference source
394-40-20
detection threshold
394-40-21
response (of a radiation measuring assembly)
394-40-22
reference response
394-40-23
resolution (of a radiation measuring assembly)
394-40-24
stability (of a radiation measuring assembly)
394-40-25
minimum detectable (measurable) activity
394-40-26
minimum detectable (measurable) concentration
394-40-27
influence quantity
394-40-28
reference conditions
394-40-29
test conditions
394-40-30
sampling test
394-40-31
linearity error
394-40-32
systematic error
394-40-33
random error
394-40-34
bias (of a measuring instrument)
394-40-35
accuracy of measurement
394-40-36
uncertainty of measurement
394-40-37
repeatability (of a measuring instrument)
394-40-38
repeatability (of results of measurements)
394-40-39
reproducibility (of results of measurements)
394-40-40
experimental standard deviation
394-40-41
verification
394-40-42
validation
394-40-43
calibration
394-40-44
calibration check
394-40-45
traceability


Copyright © IEC 2010. All Rights Reserved.