191: Dependability and quality of service
Index language:
Arabic
English
French
German
Italian
Polish
Portuguese
Spanish
Swedish
Section 191-01: Fundamental concepts
191-01-01
item
191-01-02
repaired item
191-01-03
non-repaired item
191-01-04
service
191-01-05
required function
191-01-06
functional mode
191-01-07
instant of time
191-01-08
time interval
191-01-09
(time) duration
191-01-10
accumulated time
191-01-11
measure (in the probabilistic treatment of dependability)
191-01-12
operation
191-01-13
modification (of an item)
Section 191-02: Item related performance
191-02-01
effectiveness (performance)
191-02-02
durability
191-02-03
dependability
191-02-04
capability
191-02-05
availability (performance)
191-02-06
reliability (performance)
191-02-07
maintainability (performance)
191-02-08
maintenance support performance
Section 191-04: Failures
191-04-01
failure
191-04-02
critical failure
191-04-03
non-critical failure
191-04-04
misuse failure
191-04-05
mishandling failure
191-04-06
weakness failure
191-04-07
design failure
191-04-08
manufacturing failure
191-04-09
ageing failure
191-04-10
sudden failure
191-04-11
gradual failure
191-04-12
cataleptic failure
191-04-13
relevant failure
191-04-14
non-relevant failure
191-04-15
primary failure
191-04-16
secondary failure
191-04-17
failure cause
191-04-18
failure mechanism
191-04-19
systematic failure
191-04-20
complete failure
191-04-21
partial failure
191-04-22
degradation failure
191-04-23
common cause failures
191-04-24
common mode failures
Section 191-05: Faults, errors and mistakes
191-05-01
fault
191-05-02
critical fault
191-05-03
non-critical fault
191-05-04
major fault
191-05-05
minor fault
191-05-06
misuse fault
191-05-07
mishandling fault
191-05-08
weakness fault
191-05-09
design fault
191-05-10
manufacturing fault
191-05-11
ageing fault
191-05-12
programme-sensitive fault
191-05-13
data-sensitive fault
191-05-14
complete fault
191-05-15
partial fault
191-05-16
persistent fault
191-05-17
intermittent fault
191-05-18
determinate fault
191-05-19
indeterminate fault
191-05-20
latent fault
191-05-21
systematic fault
191-05-22
fault mode
191-05-23
faulty
191-05-24
error
191-05-25
mistake
Section 191-06: Item related states
191-06-01
operating state
191-06-02
non-operating state
191-06-03
standby state
191-06-04
idle state
191-06-05
disabled state
191-06-06
external disabled state
191-06-07
down state
191-06-08
up state
191-06-09
busy state
191-06-10
critical state
191-06-11
degraded state
191-06-12
derated state
Section 191-07: Maintenance
191-07-01
maintenance
191-07-02
maintenance philosophy
191-07-03
maintenance policy
191-07-04
maintenance echelon
191-07-05
indenture level (for maintenance)
191-07-06
level of maintenance
191-07-07
preventive maintenance
191-07-08
corrective maintenance
191-07-09
controlled maintenance
191-07-10
scheduled maintenance
191-07-11
unscheduled maintenance
191-07-12
on-site maintenance
191-07-13
off-site maintenance
191-07-14
remote maintenance
191-07-15
automatic maintenance
191-07-16
deferred maintenance
191-07-17
elementary maintenance activity
191-07-18
maintenance action
191-07-19
repair
191-07-20
fault recognition
191-07-21
fault localization
191-07-22
fault diagnosis
191-07-23
fault correction
191-07-24
function check-out
191-07-25
restoration
191-07-26
supervision
191-07-27
maintenance entity
191-07-28
function-affecting maintenance
191-07-29
function-preventing maintenance
191-07-30
function-degrading maintenance
191-07-31
function-permitting maintenance
Section 191-08: Maintenance related times
191-08-01
maintenance time
191-08-02
maintenance man-hours
191-08-03
active maintenance time
191-08-04
preventive maintenance time
191-08-05
corrective maintenance time
191-08-06
active preventive maintenance time
191-08-07
active corrective maintenance time
191-08-08
undetected fault time
191-08-09
administrative delay (for corrective maintenance)
191-08-10
logistic delay
191-08-11
fault correction time
191-08-12
technical delay
191-08-13
check-out time
191-08-14
fault diagnosis time
191-08-15
fault localization time
191-08-16
repair time
Section 191-09: Item state related times
191-09-01
operating time
191-09-02
non-operating time
191-09-03
required time
191-09-04
non-required time
191-09-05
standby time
191-09-06
idle time
191-09-07
disabled time
191-09-08
down time
191-09-09
accumulated down time
191-09-10
external disabled time
191-09-11
up time
Section 191-10: Reliability performance measure related times
191-10-01
time to first failure
191-10-02
time to failure
191-10-03
time between failures
191-10-04
operating time between failures
191-10-05
time to restoration
191-10-06
useful life
191-10-07
early failure period
191-10-08
constant failure intensity period
191-10-09
constant failure rate period
191-10-10
wear-out failure period
Section 191-11: Availability performance measures
191-11-01
instantaneous availability
191-11-02
instantaneous unavailability
191-11-03
mean availability
191-11-04
mean unavailability
191-11-05
asymptotic availability
191-11-06
(steady-state) availability
191-11-07
asymptotic unavailability
191-11-08
(steady-state) unavailability
191-11-09
asymptotic mean availability
191-11-10
asymptotic mean unavailability
191-11-11
mean up time
191-11-12
mean down time
191-11-13
mean accumulated down time
Section 191-12: Reliability performance measures
191-12-01
reliability
191-12-02
(instantaneous) failure rate
191-12-03
mean failure rate
191-12-04
(instantaneous) failure intensity
191-12-05
mean failure intensity
191-12-06
mean time to first failure
191-12-07
mean time to failure
191-12-08
mean time between failures
191-12-09
mean operating time between failures
Section 191-13: Maintainability and maintenance support performance measures
191-13-01
maintainability
191-13-02
(instantaneous) repair rate
191-13-03
mean repair rate
191-13-04
mean maintenance man-hours
191-13-05
mean repair time
191-13-06
p-fractile repair time
191-13-07
mean active corrective maintenance time
191-13-08
mean time to restoration
191-13-09
fault coverage
191-13-10
repair coverage
191-13-11
mean administrative delay
191-13-12
p-fractile administrative delay
191-13-13
mean logistic delay
191-13-14
p-fractile logistic delay
Section 191-14: Test concepts
191-14-01
test
191-14-02
compliance test
191-14-03
determination test
191-14-04
laboratory test
191-14-05
field test
191-14-06
endurance test
191-14-07
accelerated test
191-14-08
step stress test
191-14-09
screening test
191-14-10
time acceleration factor
191-14-11
failure rate acceleration factor
191-14-12
failure intensity acceleration factor
191-14-13
maintainability verification
191-14-14
maintainability demonstration
191-14-15
observed data
191-14-16
test data
191-14-17
field data
191-14-18
reference data
Section 191-15: Design concepts
191-15-01
redundancy
191-15-02
active redundancy
191-15-03
standby redundancy
191-15-04
fail safe
191-15-05
fault tolerance
191-15-06
fault masking
Section 191-16: Analysis concepts
191-16-01
prediction
191-16-02
reliability model
191-16-03
fault modes and effects analysis
191-16-04
fault modes, effects and criticality analysis
191-16-05
fault tree analysis
191-16-06
stress analysis
191-16-07
reliability block diagram
191-16-08
fault tree
191-16-09
state-transition diagram
191-16-10
stress model
191-16-11
fault analysis
191-16-12
failure analysis
191-16-13
maintainability model
191-16-14
maintainability prediction
191-16-15
maintenance tree
191-16-16
maintainability allocation
Section 191-17: Improvement processes
191-17-01
learning process (for reliability)
191-17-02
burn in (for repairable hardware)
191-17-03
burn in (for a non-repairable item)
191-17-04
reliability growth
191-17-05
reliability improvement
191-17-06
reliability and maintainability management
191-17-07
reliability and maintainability assurance
191-17-08
reliability and maintainability control
191-17-09
reliability and maintainability programme
191-17-10
reliability and maintainability plan
191-17-11
reliability and maintainability audit
191-17-12
reliability and maintainability surveillance
191-17-13
design review
Section 191-18: Measure modifiers
191-18-01
true
191-18-02
predicted
191-18-03
extrapolated
191-18-04
estimated
191-18-05
intrinsic
191-18-06
operational
191-18-07
mean, noun and adjective
191-18-08
p-fractile
191-18-09
instantaneous
191-18-10
steady state
Section 191-19: Service related performance
191-19-01
quality of service
191-19-02
serveability performance
191-19-03
service accessibility performance
191-19-04
service retainability performance
191-19-05
service support performance
191-19-06
service operability performance
191-19-07
service integrity
191-19-08
transmission performance
191-19-09
trafficability performance
191-19-10
propagation performance (in telecommunications)
191-19-11
interruption (of service)
Section 191-20: Time concepts related to interruptions
191-20-01
time between interruptions
191-20-02
interruption duration
191-20-03
mean time between interruptions
191-20-04
mean interruption duration
191-20-05
mean service provisioning time
191-20-06
billing error probability
191-20-07
service user mistake probability
191-20-08
dialling mistake probability
191-20-09
service user abandonment probability
191-20-10
call abandonment probability
191-20-11
service accessibility
191-20-12
mean service access delay
191-20-13
mean access delay (of a communication)
191-20-14
p-fractile access delay (of a communication)
191-20-15
service retainability
191-20-16
connection retainability (in telecommunication)
Section 191-21: Electric power system related concepts
191-21-01
adequacy (of an electric power system)
191-21-02
credible event (in an electric power system)
191-21-03
security (of an electric power system)
191-21-04
integrity (of a bulk power system)
Section 191-22: Operating states of electric power systems
191-22-01
stable state (of an electric power system)
191-22-02
unstable state (of an electric power system)
191-22-03
adequate state (of an electric power system)
191-22-04
partially adequate state (of an electric power system)
191-22-05
inadequate state (of an electric power system)
191-22-06
alert state (of an electric power system)
191-22-07
potentially unstable state (of an electric power system)
191-22-08
potentially inadequate state (of an electric power system)
191-22-09
secure state (of an electric power system)
191-22-10
restoration process (of an electric power system)
Section 191-23: Failures (in electric power systems)
191-23-01
active failure
191-23-02
passive failure
191-23-03
cascading
Section 191-24: Outages (in electric power systems)
191-24-01
planned outage
191-24-02
unplanned outage
191-24-03
forced outage
191-24-04
deferrable outage
191-24-05
transient outage
191-24-06
sustained outage
191-24-07
permanent outage
191-24-08
temporary outage
Section 191-25: Outage occurrences (in electric power systems)
191-25-01
outage occurrence
191-25-02
single-outage occurrence
191-25-03
multiple-outage occurrence
191-25-04
related multiple-outage occurrence
191-25-05
pre-conditioned multiple-outage occurrence
191-25-06
sequential multiple-outage occurrence
191-25-07
common-cause outage occurrence
191-25-08
independent multiple-outage occurrence
Section 191-26: Interruptions
191-26-01
sustained interruption
191-26-02
momentary interruption
Section 191-27: Selected customer interruption indices
191-27-01
interruption frequency per customer served
191-27-02
interruption frequency per customer interrupted
191-27-03
service unavailability per customer served
191-27-04
service unavailability per customer interrupted
191-27-05
mean duration of a customer interruption
Section 191-28: Bulk power system failures and deficiencies
191-28-01
load not supplied
191-28-02
load interrupted
191-28-03
load shed
191-28-04
load reduction
Section 191-29: Selected performance indices
191-29-01
probability of failure to operate
191-29-02
loss-of-load expectation (of an electric power system)
191-29-03
loss-of-load probability (of an electric power system)
Section 191-30: Selected energy indices
191-30-01
expected energy not supplied
191-30-02
equivalent mean interruption duration
191-30-03
equivalent peak interruption duration
191-30-04
aggregate equivalent peak interruption duration
191-30-05
bulk power energy curtailment index