IEVref:
395-07-66
ID:
Language:
en
Status:
Standard
Term:
Campbell system, <for neutron monitoring>
Synonym1:
Synonym2:
Synonym3:
Symbol:
Definition:
assembly designed for measuring the neutron flux in a nuclear reactor, based on the fluctuation of the signal delivered by a fission ionization chamber
Note 1 to entry: The neutron fluence rate is proportional to its variance.
Publication
date
:
2014-03
Source
Replaces:
Internal notes:
CO remarks:
TC/SC remarks:
VT remarks:
Domain1:
Domain2:
Domain3:
Domain4:
Domain5:
assembly designed for measuring the neutron flux in a nuclear reactor, based on the fluctuation of the signal delivered by a fission ionization chamber
Note 1 to entry: The neutron fluence rate is proportional to its variance.